I&J4000-LF Series Operating Manual
Section 3: Teaching Overview
Part # 562187
Rev. E - Jan. 08
- Page 27 -
© 2008 I&J Fisnar Inc.
4.3 Menu
1
Below is a list of functions, which are found under the
Menu 1
key:
Function Description
Group Edit
Allows a function to be applied to a user-defined group
of memory addresses. Functions include copy, delete,
move, multiply line speed, multiply dispense times, apply
X Offset, apply Y Offset, apply Z Offset
Expand Step & Repeat
Expands the memory address locations which would be
performed at a Step & Repeat instruction so individual
memory addresses of the repeated instructions can be
edited
Program Name
Allows the user to register a name for the current
program number
Z-axis Limit (mm)
Sets the MAXIMUM Z-axis value (the lowest tip
position). Once the Z-axis limit is set, the robot will
prevent the tip from jogging below the set location.
Initial Output Port
Sets the status of the output signals when the machine
is initialized
Debug Speed (mm/s)
Sets the speed used when running in Debug mode.
Utility Menu
Menu
Jog Speed
Allows the user to set the tip jog speed for teach mode:
Low, Middle or High jog speed can be selected.
Adjust Origin
See Section 2.9 “Adjust Position Setup”
Control by RS232
Allows the robot to be controlled via the RS232 port