I&J4000-LF Series Operating Manual
Section 5: Point Type & Function Reference
Part # 562187
Rev. E - Jan. 08
- Page 38 -
© 2008 I&J Fisnar Inc.
1. Point Menu
Below is a list of functions which are found under the
ENTER
key. These functions are
‘point-type’ functions, meaning that the values applied will occupy one memory address.
Please see
for additional programming examples.
1.1 Dispense
Dot
Registers the current XYZ location as a dispense point for dot dispensing.
The dispense time and wait time must be set in a previous memory address by registering
a
Point Dispense Setup
instruction.
The upward motion of the tip after dispensing can be controlled by registering a
Dispense
End Setup
instruction and / or a
Z Clearance
instruction in a previous memory address.
Dispense End Setup
and
Z Clearance
instructions are registered using the
SETUP
key.
SECTION 5:2.3 Point Dispense Setup
,
SECTION 5:2.4 Dispense End Setup
.
1.2 Line
Start
Registers the current XYZ location as a Line Start point for line dispensing.
The line speed must be set in a previous memory address by registering a
Line
Speed
instruction using the
SETUP
key.
Dispense delay times used at Line Start and Line End points can be controlled by
registering a
Line Dispense Setup
instruction in a previous memory address. The
Line
Dispense Setup
instruction is registered by pressing the
SETUP
key.
and
SECTION 5:2.2 Line Dispense Setup
.
Содержание I&J4000-LF Series