2.3 Point Dispense Setup
Registers POINT DISPENSE SETUP values which set dispensing time and waiting time at
the end of dispensing (‘tail’ time) for dots. The registered values will be used from the
current memory address forward until another POINT DISPENSE SETUP instruction is
found.
2.4 Dispense End Setup
Dispense End Setup
allows the
L.Length
,
L. Speed
and
H. Speed
values to be registered
at a memory address. These values will effect how far and how fast the tip rises after
dispensing.
After dispensing a dot or line, it is often required to raise the tip a short distance at a slow
speed. This allows the material to cleanly break free from the tip, without ‘dragging’
material where it is not wanted.
The distance and speed that the tip raises after dispensing is controlled by the
L.Length
and
L.Speed
settings.
After the tip raises the length specified by
L.Length
at the speed specified by
L.Speed
,
the tip will continue rising to the
Z Clearance
height at the speed specified by
H.Speed
.
The purpose of specifying a Z Clearance height is to allow the tip to raise high enough to
clear any obstacles it may encounter on the way to the next point.
H.Speed
2: Tip continues rising to
Z Clearance
height at
H. Speed
L.Length
1: After dispensing, the tip
rises to
L.Length
at
L.Speed
Z Clearance