40
(2) Controller error list
Press any one of the ten keys 0
-
8 from the screen of the RC Data Input Pendant error list, then the
error that has occurred is displayed after power for the controller is turned ON. For a number of 10 or
more, press the
key and the ten keys of 0-5.
Note) The RC Data Input Pendant FLASH Ver. 1.63 and later make available the display function of
the controller error list.
For PCON, ACON, SCON and ERC2, the content of the alarm list will be kept even if the power
is turned OFF.
Displays the past 8 alarm level errors including the final (most recent) error that has occurred, and one
final detected warning level error.
The relationship between the ten keys and error to be displayed are as follows.
Display of PCON, ACON, SCON and ERC2
Display of RCP, RCS, E-Con, RCP2 and ERC
Ten key
Ten key
0
Last detected alarm level error
0
Last detected alarm level error
1
Previously first detected alarm level error
1
Previously first detected alarm level error
2
Previously second detected alarm level error
2
Previously second detected alarm level error
3
Previously third detected alarm level error
3
Previously third detected alarm level error
4
Previously fourth detected alarm level error
4
Previously fourth detected alarm level error
5
Previously fifth detected alarm level error
5
Previously fifth detected alarm level error
6
Previously sixth detected alarm level error
6
Previously sixth detected alarm level error
7
Previously seventh detected alarm level error
7
Previously seventh detected alarm level error
8
Previously eighth detected alarm level error
8
Last detected warning level error
9
Previously ninth detected alarm level error
0 Previously tenth detected alarm level error
1 Previously eleventh detected alarm level error
2 Previously twelfth detected alarm level error
3 Previously thirteenth detected alarm level error
4 Previously fourteenth detected alarm level error
5 Previously fifteenth detected alarm level error
The displayed content can be selected with the
keys or return key.
The list No. can be changed with the
keys.
Controller error list
The screen returns to the RC Data Input Pendant error list screen by pressing the
key.
Displays the error No.
CTL Err List 0
A. 00
Err No.
0B1
Displays the error name.
CTL Err List 0
A. 00
Bank 31 Err (Point)
Содержание ROBO CYLINDER RCM-P
Страница 1: ...Robo Cylinder Data Input Pendant RCM P Operating Manual Second edition IAI America Inc...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 14: ...6 6 2 External View External Dimensions...
Страница 15: ...7 6 3 Description of Each Part 1 LCD 6 Numeric keys 7 Return key 4 key 3 key 5 Minus key 2 Arrow keys...
Страница 67: ......