Solenoid Valve Method
EleCylinder products normally use a double solenoid method.
Change parameter No. 9 ("solenoid valve type selection") to use the single solenoid method.
<Caution>
Operation cannot be performed using the single solenoid method when operating connected to RCON-EC.
Basic Controller Specifications
Specification item
Specification content
Number of controlled axes
1 axis
Power supply voltage
24VDC ±10%
Power capacity (Note 1)
Rated 0.7A, max. 1.1A
Brake release power supply
24VDC ±10%, 200mA (only for external brake release)
Generated heat
2W
Inrush current (Note 2)
3A
Momentary power failure resistance
Max 500µs
Motor size
ø20
Motor rated current
0.4A
Motor control system
Weak field-magnet vector control
Supported encoders
Incremental (32768 pulse/rev)
SIO
RS-485 1ch (Modbus protocol compliant)
Interface
box
specification
Input
specification
No. of inputs
3 points (forward, backward, alarm clear)
Input voltage
24VDC ±10%
Input current
5mA per circuit
Leakage current Max. 1mA/1 point
Isolation method Non-isolated
Output
specification
No. of outputs 3 points (forward complete, backward complete, alarm)
Output voltage 24VDC ±10%
Output current 50mA/1 point
Residual voltage 2V or less
Isolation method Non-isolated
Data setting, input method
PC teaching software, touch panel teaching pendant
Data retention memory
Position and parameters are saved in non-volatile memory (no limit to number of rewrites)
LED
display
Controller status display
Servo ON (green light ON) / Alarm (red light ON) / Initializing when power comes ON (orange light
ON) / Minor failure alarm (green/red alternately blinking) / Operation from teaching: Stop from
teaching (red light ON) / Servo OFF (light OFF)
Wireless status display
Initializing wireless hardware, without wireless connection, or connecting from TP board (light OFF)
Connecting through wireless (green blinking) / Wireless hardware error (red blinking) / Initializing
when power comes ON (orange light ON)
Forward end/backward end
display (Note 3)
Lit orange: Forward end/backward end, push idling detection
Blinking orange: Push complete
Predictive maintenance/preventative
maintenance
When the number of movements or operation distance has exceeded the set value and when the
LED (right side) blinks alternately green and red at overload warning
*Only when configured in advance
Ambient operating temperature
0 ~ 40°C
Ambient operating humidity
5%RH ~ 85%RH or less (no condensation or freezing)
Operating ambience
No corrosive gas or excessive dust
Insulation resistance
500VDC 10MΩ
Electric shock protection mechanism
Class 1 basic insulation
Cooling method
Natural air cooling
(Note 1) When connecting to RCON-EC, 0.3A is subtracted from the value.
(Note 2) Inrush current flows for approximately 5ms after the power is input. (At 40°C) Inrush current value differs depending on the impedance on the power line.
(Note 3) The LED display function can be changed via parameter setting.
25