EleCylinder Series
Options
RCON-EC connection specification
Description
Model
ACR
Select when connecting to a field network via an R-unit (connected to RCON-EC).
*This usage involves direct connection to RCON-EC. When using wireless communication, separately prepare an interface box,
interface box conversion cable, and power / I/O cable connector.
Applicable models
All models
Brake
Description
Model
B
This mechanism stops the slider, rod, or table from moving when the power or servo is turned off.
When mounting the actuator vertically, this option is required.
Applicable models
All models
PN specification
*Cannot be selected simultaneously with the ACR option
Description
Model
PN
For I/O specification, NPN is the standard specification.
Specifying this option changes input/output to the PNP specification.
Applicable models
All models
Non-motor end specification
Description
Model
NM
The home position is normally set to the motor side. This option is for setting the home position on the other side in order to
accommodate variations in equipment layout, etc.
Applicable models
All models
Cable exit direction
Description
Model
Applicable models
All models
CJB/CJL/CJR/CJT
The mounting direction of the actuator cable mounted on the actuator body can be changed among top, bottom, left, and right.
Bottom: CJB
Left: CJL
Right: CJR
Top: CJT
Split motor and controller power supply specification
* Cannot be selected with the ACR option (the RCON-EC connection specification is a split motor and controller power supply specification)
Description
Model
TMD2
This option provides a separate motor power supply and control power supply. Select to allow shutting down the actuator drive power only.
Please refer to P. 26 for more information on wiring.
Applicable models
All models
Wireless axis operation support specification
*Cannot be selected simultaneously with the ACR option
Description
Model
WL2
Specifying WL2 allows for the product to operate wirelessly as with WL (start point, end point, and AVD adjustment), and to also perform axis travel
operation tests (forward end/backward end movement, jog, and inching). However, this function is not meant to perform automatic operation.
Refer to P. 118 of the EleCylinder Catalog V10 for precautions on axis operations using a wireless connection.
(Note) Customers cannot change WL to WL2, or WL2 to WL. Please contact IAI for this. When using wireless communication with RCON-EC
connection, separately prepare an interface box, conversion cable, and power / I/O cable connector.
Applicable models
All models
Wireless communication specification
*Cannot be selected simultaneously with the ACR option
Description
Model
WL
This option enables support for wireless communication. Specifying this option enables wireless communication with the TB-03 teaching pendant.
The start point, end point, and AVD can be adjusted via wireless communication.
When using wireless communication with RCON-EC connection, separately prepare an interface box, conversion cable, and power / I/O cable connector.
Applicable models
All models
19