Function Code Table
I5300 User Manual
- 96 -
F
unction
Code
Parameter Name
Setting Range
Default
Property
P
6-08 Time proportion of S-curve
start segment
0.0% to (100.0% – P6-09)
30.0%
★
P
6-09 Time proportion of S-curve
end segment
0.0% to (100.0% – P6-08)
30.0%
★
P
6-10 Stop mode
0: Decelerate to stop
1: Coast to stop
0
☆
P
6-11 Initial frequency of stop DC
braking
0.00 Hz to maximum frequency
0.00 Hz
☆
P
6-12 Waiting time of stop DC
braking
0.0–36.0s
0.0s
☆
P
6-13 Stop DC braking current
0%–100%
0%
☆
P
6-14 Stop DC braking time
0.0–36.0s
0.0s
☆
P
6-15
B
rake use ratio
0%–100%
100%
☆
Group
P
7: Operation Panel and Display
P
7-01 M
F
.K Key function selection
0: MF.K key disabled
1: Switchover between operation
panel control and remote
command control (terminal or
communication)
2: Switchover between forward
rotation and reverse rotation
3: Forward JOG
4: Reverse JOG
0
★
P
7-02 STOP/RESET key function
0: STOP/RESET key enabled
only in operation panel control
1: STOP/RESET key enabled in
any operation mode
1
☆
P
7-03
LED display running
parameters 1
0000–FFFF
Bit00: Running frequency 1 (Hz)
Bit01: Set frequency (Hz)
Bit02: Bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input status
1
F
☆
Содержание I5300 Series
Страница 8: ......
Страница 9: ...1 Safety Information and Precautions ...
Страница 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Страница 17: ...2 Product Information ...
Страница 28: ...Product Information I5300 User Manual 28 ...
Страница 29: ...3 Mechanical and Electrical Installation ...
Страница 45: ...4 Operation Display and Application Examples ...
Страница 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Страница 79: ...5 Function Code Table ...
Страница 135: ...6 Description of Function Codes ...
Страница 247: ...7 EMC ...