- 141 -
F
unction Code
Parameter Name
Setting Range
Default
P
0-07
F
requency source
selection
Unit's digit (
F
requency source selection)
0
0: Main frequency source X
1: X and Y operation
(operation relationship determined by ten's
digit)
2: Switchover between X and Y
3: Switchover between X and "X and Y
operation"
4: Switchover between Y and "X and Y
operation"
Ten's digit (X and Y operation relationship)
0: X+Y
1: X-Y
2: Maximum
3: Minimum
It is used to select the frequency setting channel. If the frequency source involves X and
Y operation, you can set the frequency offset in P0-21 for superposition to the X and Y
operation result, flexibly satisfying various requirements.
Figure 6-1 Frequency setting based on main frequency source X and auxiliary frequency
source Y
Frequency
source selection
Frequency source X and
Y operation selection
Setting of operation
conditions
Target running
frequency
P
0-07 unit's
digit
Set frequency
Frequency
switchover
P
4-00
to P
4-09
= 18
DI1 to DI10
P
0-07 ten's
digit
Amplitude
limit
Auxiliary
frequency
source Y
Main
frequency
source X
I5300 User Manual Description of Function Codes
Содержание I5300 Series
Страница 8: ......
Страница 9: ...1 Safety Information and Precautions ...
Страница 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Страница 17: ...2 Product Information ...
Страница 28: ...Product Information I5300 User Manual 28 ...
Страница 29: ...3 Mechanical and Electrical Installation ...
Страница 45: ...4 Operation Display and Application Examples ...
Страница 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Страница 79: ...5 Function Code Table ...
Страница 135: ...6 Description of Function Codes ...
Страница 247: ...7 EMC ...
Страница 255: ...8 Selection and Dimensions ...
Страница 261: ...9 Maintenance and Troubleshooting ...