I5300 User Manual Function Code Table
- 123 -
F
unction
Code
Parameter Name
Setting Range
Default
Property
A3-34 Number of pole pairs of
resolver
1–65535
1
★
A3-36 Encoder wire-break fault
detection time
0.0s: No action
0.1–10.0s
0.0s
★
A3-37 Auto-tuning selection
0: No auto-tuning
1: Asynchronous motor static
auto-tuning
2: Asynchronous motor complete
auto-tuning
11: Synchronous motor with-load
auto-tuning
12: Synchronous motor no-load
auto-tuning
0
★
A3-38
Speed loop proportional gain 1
0–100
30
☆
A3-39 Speed loop integral time 1
0.01–10.00s
0.50s
☆
A3-40 Switchover frequency 1
0.00 to A2-43
5.00 Hz
☆
A3-41
Speed loop proportional gain 2
0–100
15
☆
A3-42 Speed loop integral time 2
0.01–10.00s
1.00s
☆
A3-43 Switchover frequency 2
A2-40 to maximum output
frequency
10.00 Hz
☆
A3-44 Vector control slip gain
50%–200%
100%
☆
A3-45 Time constant of speed loop
fi
lter
0.000–0.100s
0.000s
☆
A3-46 Vector control over-
excitation gain
0–200
64
☆
A3-47 Torque upper limit source in
speed control mode
0: A2-48
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Via communication
6: MIN (AI1,AI2)
7: MAX (AI1,AI2)
0
☆
A3-48
Digital setting of torque
upper limit in speed control
mode
0.0%–200.0%
150.0%
☆
A3-51 Excitation adjustment
proportional gain
0–20000
2000
☆
A3-52 Excitation adjustment
integral gain
0–20000
1300
☆
Содержание I5300 Series
Страница 8: ......
Страница 9: ...1 Safety Information and Precautions ...
Страница 16: ...Safety Information and Precautions I5300 User Manual 16 ...
Страница 17: ...2 Product Information ...
Страница 28: ...Product Information I5300 User Manual 28 ...
Страница 29: ...3 Mechanical and Electrical Installation ...
Страница 45: ...4 Operation Display and Application Examples ...
Страница 78: ...Operation Display and Application Examples I5300 User Manual 78 ...
Страница 79: ...5 Function Code Table ...
Страница 135: ...6 Description of Function Codes ...
Страница 247: ...7 EMC ...
Страница 255: ...8 Selection and Dimensions ...
Страница 261: ...9 Maintenance and Troubleshooting ...