value shall be no less than 1
x
10
3
Ω
. Measure tem
perature gage resistance – the value shall corre
spond to the stated in the thermostat certificate
value.
J
Install the thermostat and service box and make all
the electrical connections. Connect the thermostat
while power is switched off.
J
Shortly (for 1–2 minutes) apply voltage and check
for integrity of the system (a LED on the face panel of
the thermostat shall light). Turn off the power and do
not turn it on until the system is put into service.
J
Mark the thermostat, service box, temperature
gage and heating section locations on the room
plan, as well as the make of the heating section and
measured heating section and temperature gage
resistance values.