4.2. Heating sections layout
Heating sections shall not be located in the places
where furniture without legs will be put. Consider placing
your heating sections in free from such furniture areas.
Do not use the same section to heat rooms of differ
ent types, e.g. bathroom and hallway or kitchen. Also do
not use the same section to heat rooms with different
floor types. Independent floor heating systems are nec
essary for such rooms, each with a separate thermostat.
4.3. Wiring and thermostat location
Make sure that the wiring in your room allows for the
I-WARM floor heating system extra power consumption.
Maximum currents for systems with different ratings are
given in the Appendix.
Consider additional appliances which could be fed
from the same circuit.
Find out permissible currents of protective equipment
(circuit breakers).
Standard wiring according to PUE (Electrical Code,
rev. 2001) can withstand the following currents and loads
(table 1).
We recommend you to connect heating systems with
2 kW total power via separate wiring with an additional cir
cuit breaker.
www.iwarm.com
Spooled Underfloor Heating Kit
10