COBALT Pro
™
Wall Sensor Retrofit Kit for
Exposed Flush Valve Installation Instructions
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents
Part No. 101675
page 6
Rev 080323
Step 3
Feed the solenoid cable conduit through the wall flange,
then feed the cable through the wall.
Step 4
Attach the wall flange to the wall using the screws provided.
Lock the conduit in place using the set screw on the wall flange.
INTERFACE MODULE INSTALLATION
Step 1
Open interface module. Mount to flat surface in chase. Use wall
anchors and screws provided.
NOTE:
The solenoid cable is 48”
long and has 18” of conduit. Ensure the solenoid cable can be
easily plugged into the interface box.
Step 2
Connect cables for pressure and temperature sensor, control
module, solenoid, and power.
Step 3
Plug-in transformer. Power on interface module using external
power switch. Close interface module.