COBALT Pro

 Wall Sensor Retrofit Kit for

Exposed Flush Valve Installation Instructions

I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

Part No. 101675

page 5

Rev 080323

Step 3

Loosen set screw on face plate. Remove cover by pulling out 

then up.

Step 4

Feed control module cable through 1-1/2” opening. 

Attach control module to wall with provided screws.

Step 5

Reattach and secure face plate with set screw.

MOUNTING WALL FLANGE

Step 1

Drill the necessary holes to mount the wall flange. Refer to the 

dimensional drawing below. 

NOTE:

 The solenoid cable is 48” 

 

long and has 18” of conduit. Please allow for enough cable 

 

to go through the wall and plug into the interface box.

1"

25

3

16 "

5

3

16 "

5

  1"

25

 

  1"

25

 

COMMERCIAL CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-CUTSHEET-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .004

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 3"x3"

CENTURY GOTHIC SIZE 8 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

PARAMETERS TO MEET

INDICATE A CENTERLINE OF FIXTURE

INDICATE A CENTERLINE OF SUPPLY FOR CONCEALED SYSTEMS

INDICATE A CENTERLINE OF WALL SENSOR WHEN APPLICABLE

Step 2

Insert wall anchors into holes.

Содержание COBALT Pro 101675

Страница 1: ...ommercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 year...

Страница 2: ...x 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE AN...

Страница 3: ...com patents Part No 101675 page 3 Rev 080323 Step 5 Install actuator cover ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square...

Страница 4: ...rough junction box knock out Attach control module to junction box with provided screws Step 3 Reattach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Ste...

Страница 5: ...g out then up Step 4 Feed control module cable through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw MOUNTING WALL FLANGE Step 1...

Страница 6: ...eed the cable through the wall Step 4 Attach the wall flange to the wall using the screws provided Lock the conduit in place using the set screw on the wall flange INTERFACE MODULE INSTALLATION Step 1...

Страница 7: ...ve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the fixtu...

Страница 8: ...e quick action button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and...

Страница 9: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...

Отзывы: