background image

COBALT Pro

 Wall Sensor Retrofit Kit for

Exposed Flush Valve Installation Instructions

I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

Part No. 101675

page 2

Rev 080323

ELECTRICAL BOX INSTALLATION

Step 1

Install 2-gang electrical box (4” x 4” x 2-1/2”). The location will 

vary based on the rough-in. Refer to the rough-in drawings for 

specific mounting location. Use a GFCI plaster ring.

4X4 JUNCTION

BOX

GFCI PLASTER RING

I-CON IR PLATE

AN I-CON IR PLATE MOUNTS TO

GFCI JUNCTION BOX COVERS

EXISTING COMPONENT REMOVAL

Step 1

Remove control stop cap.

Step 2

Turn adjustment screw 

CLOCKWISE

 to close control stop.

Step 3

Activate flush valve to relieve water pressure.

Step 4

Use strap wrench to remove flush valve cap. Remove actuator 

assembly and all inner components. Inner components commonly 

include a diaphragm, trip mechanism, and plastic internal cap.

Содержание COBALT Pro 101675

Страница 1: ...ommercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 year...

Страница 2: ...x 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE AN...

Страница 3: ...com patents Part No 101675 page 3 Rev 080323 Step 5 Install actuator cover ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square...

Страница 4: ...rough junction box knock out Attach control module to junction box with provided screws Step 3 Reattach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Ste...

Страница 5: ...g out then up Step 4 Feed control module cable through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw MOUNTING WALL FLANGE Step 1...

Страница 6: ...eed the cable through the wall Step 4 Attach the wall flange to the wall using the screws provided Lock the conduit in place using the set screw on the wall flange INTERFACE MODULE INSTALLATION Step 1...

Страница 7: ...ve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the fixtu...

Страница 8: ...e quick action button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and...

Страница 9: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...

Отзывы: