COBALT Pro
™
Wall Sensor Retrofit Kit for
Exposed Flush Valve Installation Instructions
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents
Part No. 101675
page 8
Rev 080323
Full
Flush
Count
Reset
AUTO-RANGE
To set range automatically, press and hold the auto range quick
action button for 3 seconds. Place target at desired detection
range within 5 seconds. Green light blinks every second during
countdown. Sensor will lock on to target, indicated by solid green
light. Green light will blink to confirm range is set.
NOTE:
Test range with targets of various colors and textures for
accuracy. Ensure foreign objects, such as stall doors and mirrors,
are not detected.
PROFILE
To view current profile, press and release profile quick action
button. Current profile number is displayed through LED
illuminations and the digital display. To change profile, press
and release profile quick action button again. Continue to press
and release profile quick action button until desired profile is
displayed. Press and hold profile quick action button for 3
seconds to set profile. Blue lights will flash to indicate profile
was saved.
Display
Profile
Flush Volume
P1 - Red & Blue
Profile 1
10% Water Savings
P2 - Blue
Profile 2
5% Water Savings
P3 - Green & Blue
Profile 3
Standard Flush Volume
ACTIVATE
Activates a full flush of the flush valve.
ACTIVATION COUNT RESET
The activation count can be monitored by using the onboard
display. It will display AC (Activation Count) followed by the
number of activations since the last rebuild. A red LED blinking
alarm will begin once the activation count has surpassed 250,000
cycles. At this time, it is recommended to rebuild the valve. To
reset this alarm, press and hold the activation count reset for
5 seconds. The red LED will flash indicating the count has been
reset to 0.
INSTALLATION COMPLETE