4.3.21 Group H Screen 1
‘Group H Screen 1’ screen panel comes out when ‘H code’ button in function selecting menu or UP
(
) button or DOWN button (
) in ‘Group H Screen 2’ screen panel is touched. Constant values
for the motor are set in this screen panel. The set values are used for the sensorless vector control
or the vector control.
Figure 28 Group H screen 1
When touching any button in the sreen panel, 10KEY screen comes out for inputting values. (Refer
to [Input way of 10KEY screen]).
(1)
Stator resistance: set stator resistance for the motor in [OHM] unit.
(2)
Stator inductance: set stator inductance for the motor in [mH] unit.
(3)
Rotor resistance: set rotor resistance for the motor in [OHM] unit.
(4)
Rotor inductance: set rotor inductance for the motor in [mH] unit.
(5)
Mutual inductance: set mutual inductance for the motor in [mH] unit.
(6)
Inertia factor: set inertia factor of the motor.