18
C
C
C
Chapter3. Specification and Operation
hapter3. Specification and Operation
hapter3. Specification and Operation
hapter3. Specification and Operation
N5000 INSTRUCTION MANUAL
N5000 INSTRUCTION MANUAL
N5000 INSTRUCTION MANUAL
N5000 INSTRUCTION MANUAL
Figure 3-10 output voltage curve of a power cell
Also, 25 levels (13 levels for 3kV-class) quasi-sinewave outpt based on the line voltage can be
achieved when the serially connected 6 power cell unit outputs that are allocated to each phase
have phase differences. This output characteristic of N5000 makes it to operate pre-installed
motors without additional filter.
Figure 3-11 voltage output curve of 6kV-class N5000 inverter
3.3.4 Control Function
Control part of N5000 inverter is composed of main control part, which is in charge of system
operations, controls, failure detections and protections, and the power cell controller that is
installed in the power cell. Main control part is located at the left side of control panel and