5-52-3
侍#
Some fault codes are not applied to this machine.
J1939 Code
Description
Effect and Action
7441-4
Aftertreatment Ambient Air
Temperature : Voltage Below Normal
The ECM detects the following conditions:
The signal voltage from the aftertreatment ambient air
temperature sensor is less than 0.2 VDC for more than 8
seconds.
An active diagnostic code will be generated after 8 seconds.
The diagnostic code will be logged if the engine has been
operating for more than 7 minutes “Voltage Below Normal”
will be displayed next to the status for "Afrertreatment
Ambient Air Temperature" on the electronic service tool.
Sensor Signal (Analog, Passive) - Test
Содержание HX140L
Страница 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 209: ...4 5 MEMORANDUM...
Страница 275: ...4 49 No of pin Receptacle connector female Plug connector male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 675: ...8 58 29 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 703: ...8 77 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Страница 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 767: ...8 141 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...