5-47
J1939 Code
Description
Effect and Action
3509-4
Sensor Supply Voltage 1 : Voltage
Below Normal
The ECM detects the following conditions:
The 5 VDC supply for the sensors is less than 4.84 VDC for
more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-4 is not active.
The warning lamp will come on. The ECM sets all the
sensors on the 5 VDC circuit to the default values.
The engine will be derated.
5 V Sensor Supply Circuit - Test
3510-3
Sensor Supply Voltage 2 : Voltage
Above Normal
The Electronic Control Module (ECM) detects the following
conditions:
The 5 VDC supply for the sensors is greater than 5.16 VDC
for more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-4 is not active.
The warning lamp will come on. The ECM sets all the
sensors on the 5 VDC circuit to the default values.
The engine will be derated.
5 V Sensor Supply Circuit - Test
3510-4
Sensor Supply Voltage 2 : Voltage
Below Normal
The ECM detects the following conditions:
The 5 VDC supply for the sensors is less than 4.84 VDC for
more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-4 is not active.
The warning lamp will come on. The ECM sets all the
sensors on the 5 VDC circuit to the default values.
The engine will be derated.
5 V Sensor Supply Circuit - Test
3511-3
Sensor Supply Voltage 3 : Voltage
Above Normal
DEF/AdBlue® Pump Sensor Supply - Test
3511-4
Sensor Supply Voltage 3 : Voltage
Below Normal
DEF/AdBlue® Pump Sensor Supply - Test
3512-3
Sensor Supply Voltage 4 : Voltage
Above Normal
The ECM detects the following conditions:
The 8 VDC supply is more than 8.8 VDC for more than one
second.
The ECM has been powered for more than 3 seconds.
Diagnostic code 168-4 is not active.
The ECM will log the diagnostic code and the warning lamp
will illuminate while this diagnostic code is active.
The engine may be limited to low idle.
Speed/Timing - Test
3512-4
Sensor Supply Voltage 4 : Voltage
Below Normal
The ECM detects the following conditions:
The 8 VDC supply is less than 7.2 VDC for more than one
second.
The ECM has been powered for more than 3 seconds.
Diagnostic code 168-4 is not active.
The ECM will log the diagnostic code and the warning lamp
will illuminate while this diagnostic code is active.
The engine may be limited to low idle.
An active diagnostic code may not cause any noticeable
effect on engine response unless the voltage drops below
6.5 VDC.
Speed/Timing - Test
侍#
Some fault codes are not applied to this machine.
Содержание HX140L
Страница 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Страница 209: ...4 5 MEMORANDUM...
Страница 275: ...4 49 No of pin Receptacle connector female Plug connector male 14 1 7 6 14 MG610406 KET SDL CONNECTOR 13...
Страница 675: ...8 58 29 Insert O rings to the relief valve 30 and reassemble them to rear cover 20 This completes assembly 17 32038SM42...
Страница 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Страница 703: ...8 77 125LCR8TM61 After assembling spring 44 in order clamp plug 41 Tightening torque 5 kgf m 36 lbf ft 31...
Страница 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Страница 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...
Страница 767: ...8 141 14 15 3 Install cover 3 to body 1 and tighten bolts 14 Torque 10 12 5 kgf m 72 3 90 4 lbf ft 7 21078DA10...