OPERATION
2
4-2
powermax
1650
Operator Manual
Controls and indicators
_
+
4.0
5.0
50
60
AC
70
80
V
BAR
6.0
PSI
AMPS
30
40
100
80
60
Current (amps)
adjustment /
gas test knob
Mode switch
Indicator
LEDs
Pressure gauge
Pressure
regulator
ON (I) / OFF (0) switch
Green power ON LED
When illuminated, indicates that power is applied to the system and the power switch is
ON ( I ).
Gas
p
ressure LED
Yellow:
When flashing, indicates that the gas pressure is below 65 psig (4.5 bar) for
cutting, or 40 psig (2.8 bar) for gouging.
Green:
When illuminated, indicates that there is acceptable gas pressure for torch
operation.
Yellow
t
orch
c
ap LED
When illuminated, indicates that the retaining cap is loose or not installed.
NOTE: This condition must be corrected and the power turned OFF and then ON
again to clear the LED.
Yellow
temperature
LED
When illuminated, indicates that the power supply temperature has exceeded its operating
limit
.
Red
f
ault LED
When illuminated, indicates that a fault condition exists, which prevents system operation.
A yellow LED should also be illuminated to identify the type of fault.
Yellow
l
ine
v
oltage LED
When illuminated, indicates that line voltage is below 170 VAC, above 680 VAC, or
missing a phase.
AC
V
Indicator LEDs
Содержание powermax1650
Страница 10: ...WARRANTY vi Hypertherm ...
Страница 14: ...TABLE OF CONTENTS 0 x powermax1650 Operator Manual ...
Страница 26: ...1 12 Hypertherm 11 08 SAFETY ...
Страница 38: ...11 08 1a 12 Hypertherm SÉCURITÉ ...
Страница 50: ...11 08 SEGURIDAD 1b 12 Hypertherm ...
Страница 106: ...MAINTENANCE AND PARTS 0 5 12 powermax1650 Operator Manual ...