OPeRATION
Duramax Retrofit Torch
Operator Manual
3-31
65 A Unshielded
Mild Steel
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings
Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds
mm/min
Volts
mm/min
Volts
2
2.0
5.0
250
0.1
6050
117
7340
117
3
0.2
5200
118
6330
118
4
0.5
4250
118
5250
118
6
2550
120
3560
120
8
1620
123
2230
121
10
6.0
300
0.7
970
127
1500
122
12
Edge Start
760
129
1140
124
16
500
134
650
129
20
280
138
400
133
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings
Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
16 GA
0.08
0.20
250
0.1
255
116
308
117
10 GA
190
118
232
118
3/16
0.2
135
119
172
119
1/4
0.5
90
120
116
120
3/8
0.24
300
0.7
40
126
62
122
1/2
Edge Start
27
130
40
125
5/8
20
134
26
129
3/4
13
137
18
132
Содержание HRT
Страница 1: ...Duramax Retrofit Torch HRT HRTs MRT Operator Manual 807190 Revision 1 ...
Страница 2: ......
Страница 10: ...WARRANTY 9 10 W 4 Compliance Information ...
Страница 16: ...Specifications 1 4 Duramax Retrofit Torch Operator Manual ...
Страница 34: ...Torch setup 2 18 Duramax Retrofit Torch Operator Manual ...
Страница 88: ...OPERATION 3 54 Duramax Retrofit Torch Operator Manual ...