OPeRATION
Duramax Retrofit Torch
Operator Manual
3-25
Note:
Torch-to-work dis tance for the following cut chart is 3/16 in (4.8 mm) for all cuts.
Arc
current
Arc
voltage
Pierce
delay
Material thickness
Recommended cut
speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
100
136
0.5
1/4
6.4
137
3479
210
5334
139
0.5
3/8
9.5
79
2006
122
3098
142
1.0
1/2
12.7
59
1498
91
2311
146
1.0
5/8
15.9
37
939
57
1447
150
1.5
3/4
19.0
28
711
43
1092
155
NA
1
25.4
17
431
26
660
160
1 1/4
31.8
10
254
16
406
Arc
current
Arc
voltage
Pierce
delay
Material thickness
Recommended cut
speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
100
137
0.5
1/4
6.4
166
4216
255
6477
139
0.5
3/8
9.5
99
2514
153
3886
142
1.0
1/2
12.7
70
1778
107
2717
147
1.0
5/8
15.9
50
1270
77
1955
150
1.5
3/4
19.0
33
838
51
1295
154
NA
1
25.4
20
508
31
787
Mild steel
Stainless steel
Aluminum
Arc
current
Arc
voltage
Pierce
delay
Material thickness
Recommended cut
speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
100
136
0.5
1/4
6.4
157
3987
241
6121
139
0.5
3/8
9.5
85
2159
131
3327
142
1.0
1/2
12.7
53
1346
81
2057
146
1.0
5/8
15.9
33
838
51
1295
150
1.5
3/4
19.0
22
558
33
838
155
NA
1
25.4
14
355
22
558
161
1 1/4
31.8
7
177
11
279
Содержание HRT
Страница 1: ...Duramax Retrofit Torch HRT HRTs MRT Operator Manual 807190 Revision 1 ...
Страница 2: ......
Страница 10: ...WARRANTY 9 10 W 4 Compliance Information ...
Страница 16: ...Specifications 1 4 Duramax Retrofit Torch Operator Manual ...
Страница 34: ...Torch setup 2 18 Duramax Retrofit Torch Operator Manual ...
Страница 88: ...OPERATION 3 54 Duramax Retrofit Torch Operator Manual ...