OPeRATION
Duramax Retrofit Torch
Operator Manual
3-23
45 A Shielded
Aluminum
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds mm/min
Volts
mm/min
Volts
1
1.5
3.8
250
0.0
8250
136
11000
136
2
0.1
6600
136
9200
135
3
0.2
3100
139
6250
134
4
0.4
2200
141
4850
135
6
0.5
1500
142
2800
137
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
1/32
0.06
0.15
250
0.0
325
136
450
136
1/16
0.1
325
136
400
136
3/32
0.2
200
136
328
134
1/8
0.4
100
140
224
134
1/4
0.5
54
142
96
137