WARNING AND ERROR MESSAGE
In case of an error the screen will display the cause of error and emit an audible sound.
Incorrect polarity connected. WARNING check your batteries
power lines
The battery has become disconnected or error.
CONNECT ERROR
CHECK MAIN PORT
The
main power leads of your battery is not connected.
The cell number is wrong.
CELL NUMBER
INCORRECT
Voltage of one cell in the battery pack is too high. Warning this may
cause to battery damage or fire.
CELL ERROR
HIGH VOLTAGE
Voltage of one cell in the battery pack is too low. Check your battery
for issue.
CELL ERROR
LOW VOLTAGE
The internal temperature of the unit is too high. Warning this may
cause damage to the charger or battery.
INT.TEMP.TOO HI
DC IN TOO LOW
The input voltage of the charger is less than 11V. Check you power
supply source
The input voltage to your charger is higher than 30V. Warning reduce
input voltage or charger may become damaged.
DC IN TOO HIGH
BATTERY WAS FULL
The battery voltage is higher than the maximum voltage
allowed while in Balance Mode. Warning check battery.
CELL ERROR
VOLTAGE-INVALID
Voltage of one cell in the battery pack is invalid. Recheck your
battery packs serial (S) settings.
The external temperature of the battery is too high. Warning this
may be because of a possible overcharge.
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
The battery capacity charged is more than the maximum
capacity set by the user.
OVER TIME LIMIT
The charging time is longer than the set time by the user.
BALANCE CONNECT
ERROR
The
balance
connector of your battery is not connected
.
21 ·