Page 29
10.4 Steam cylinder, electrodes
and cylinder base cleaning
For cleaning, mechanical removal of the
deposits is usually sufficient.
Risk of functional disruption!
When using acids or other chemicals for
cleaning, thoroughly flushing and rinsing is
essential otherwise cylinder water conductiv-
ity may be impaired.
Steam cylinder cleaning
»
Check the inside of the top part of
steam cylinder for crust build-up and
possible salt bridges (black grooves
between the electrode leads). If pre-
sent, wash away/scrape off comple-
tely.
If electrical arcs have burned deep grooves
into the material, the complete cylinder must
be replaced.
Electrode cleaning
»
Clean the sensor electrode until
metallically bright.
»
Clean electrodes and check elec-
trode wear (s. „Changing electro-
des“ section).
Cylinder base cleaning
»
Just as the cylinder, the cylinder
base and its connection joints must
be checked for deposits and be
cleaned, if required.
Reinstallation of the steam cylinder is to be
performed as described in the „Cylinder
removal and reinstallation“ section.
10.5 Checking cable connec-
tions
Risk of functional disruption!
Risk of material damage!
Loose cable connections may result in
increased transition resistance and contact
area overheating.
»
Check all cabling screw terminals
and plugs for tight seating. Plugs
must sit on their respective contacts
as far as they will go.
Clean cylinder interior.