Page 44
9.3
Cleaning and Maintenance
*The frequency of cleaning may have to be adjusted depending
on the quality of the compressed air and water used for opera-
tion.
9.4
Cleaning the Vacuum Nozzle
Warning:
Do not use abrasive cleaners, solvents or concentra-
ted acids!
Warning:
Do not unscrew the nozzle tip (3) from the nozzle!
»
Shut off the atomisation system as specified in Section
5.3.
»
Unscrew nozzle cap (1).
»
With a soft, lint free cloth, rub clean the inside and out-
side of the nozzle cap. Clear deposits from the hole of
Cycle
Task
monthly*
·
Clean the vacuum valve as specified in
Section 7.4; check water filter, clean and
replace flter cartridge if necessary
semiannually
·
"Visually check and test all electrical and
pneumatic components
Location
Designation
1
nozzle cap
2
o-ring
3
nozzle tip
4
nozzle body
5
nozzle cover
Содержание CU-1
Страница 1: ...Atomising Vacuum Nozzle System Manual...
Страница 37: ...Page 37 5 4 Example of Installation Fig Example of installation a VN Unit with 4 nozzles...
Страница 38: ...Page 38 Fig Example of installation a VN Unit with 8 VN nozzles and 2 vacuum valves...
Страница 48: ...Page 48 10 EC Declaration of Conformity...
Страница 54: ...Page 54 General 39 Water Installation 39 Wiring Diagram 42...