Page 40
7.
Compressed Air Connection
Warning:
For installation, note the following:
Have all work performed by a professional.
Warning:
Use compressed air of breathable air quality only!
This meets Class 1 standards as specified in DIN ISO 8573-1.
Note:
The air filter for the nozzle system has a pore size of 5
µm; it acts as protection for the nozzle system against impurities
in the plumbing. For breathable air quality, a separate filter - usu-
ally in the compressor - is required!
•
The compressed air supply temperature may notex-
ceed 40°C.
•
Compressed Air Connection: 5 - 10 bar
•
compressed air supply line:minimum DN 8
7.1
Installing the Compressed Air Connection
»
Install a shut-off valve (SV) in front of the air filter
»
Install an air filter (5µm).
Class 1 compressed air as specified by DIN ISO 8573-1
residual oil content
0,01 mg/m³
maximum dirt parti-
cle size
0,1 µm
Air filter
Skillair
Inlet
10/8 mm
Outlet
10/8 mm
Содержание CU-1
Страница 1: ...Atomising Vacuum Nozzle System Manual...
Страница 37: ...Page 37 5 4 Example of Installation Fig Example of installation a VN Unit with 4 nozzles...
Страница 38: ...Page 38 Fig Example of installation a VN Unit with 8 VN nozzles and 2 vacuum valves...
Страница 48: ...Page 48 10 EC Declaration of Conformity...
Страница 54: ...Page 54 General 39 Water Installation 39 Wiring Diagram 42...