background image

IMPORTANT WARNING - PLEASE READ

System  Flushing:

This  reverse  osmosis  system  contains  a  preservative  solution  to  prevent

microbiological growth and freezing which if ingested may cause irritation of the gastrointestinal tract,
colic, diarrhea or other symptoms. Therefore, approximately 5 gallons of water must be drawn from the
tap  to  flush  out  the  preservative  solution  before  using  the  system.  This  volume  of  water  represents
approximately two days of production. The water flushed should be disposed of to the drain.

Feed  WaterQuality:

This  reverse  osmosis  drinking  water  system  is  not  intended  to  be  used  for  the

treatment  of  water  that  is  microbiologically  unsafe  or  of  unknown  quality.  If  the  feed  water  quality  is
unsafe or unknown, have a sample of the water tested by a qualified laboratory or agency and implement
the necessary measures to ensure a safe water supply.

Содержание Economy

Страница 1: ...Reverse Osmosis Drinking Water System Installation Operation and Service Manual 90013 Rev 11 08...

Страница 2: ...h out the preservative solution before using the system This volume of water represents approximately two days of production The water flushed should be disposed of to the drain Feed Water Quality Thi...

Страница 3: ...supplied items checklist 2 Installation 3 Startup and Operation 7 Maintenance 8 Sanitization Procedures 9 Maintenance Schedule 12 Parts List and Drawing for E75TFC 3SF E50TFC 3SF 13 Reverse Osmosis D...

Страница 4: ...y from the tap Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from plain tap water Automatic Ice Makers a water line...

Страница 5: ...e faucet permeate flows from the storage tank through the post carbon filter This filter contains granulated activated carbon removing any taste and odor that has accumulated while stored in the tank...

Страница 6: ...be easily removed from under the sink Avoid placing the storage tank in out of the way cabinets or dead spaces There are two reasons for this 1 the difficulty of installation increases significantly a...

Страница 7: ...than the one serving the garbage disposal Before making a connection as shown in Figure 4 please check with code authorities Figure 4 Drain Saddle Assembly 4 Installation of Feed Water Assembly The s...

Страница 8: ...emove all burrs and sharp edges e Immediately clean up the sink area NOTE If an enamel or porcelain sink is encountered it is very important that the layer of porcelain be removed before following the...

Страница 9: ...or the palm of your hand push the membrane all the way into the housing Important Do not use force and ensure that the membrane is not protruding from the housing 6 Replace the membrane housing end ca...

Страница 10: ...de of the Pre Carbon Filter to the Auto Shut Off Valve Direct tubing into a pail or catch basin b Turn on the feed water by opening the needle valve on the feed water saddle valve and catch the water...

Страница 11: ...s The life of the membrane can be determined by measuring the percentage of rejection of total dissolved solids in the water The membrane should be replaced every 24 to 36 months when its efficiency w...

Страница 12: ...onents DO NOT USE SCOURING PADS OR ANY OTHER TYPE OF INSTRUMENT THAT COULD POTENTIALLY SCRATCH THE SURFACES OF THE UNIT Measuring spoon or device Household bleach typically containing 5 25 of chlorine...

Страница 13: ...SINFECTED SURFACE Unless the membrane element is being replaced at this time then discard the old membrane STEP 4 OPEN THE FILTER SUMPS WITH THE SUMP WRENCH SUPPLIED AND REMOVE THE CARTRIDGES STEP 5 C...

Страница 14: ...0 ALLOW THE SYSTEM TO SIT WITH THE DILUTED SANITIZING SOLUTION FOR APPROXIMATELY 20 MINUTES STEP 11 OPEN THE FAUCET AND PURGE THE TANK AND SYSTEM OF THE SANITIZING SOLUTION STEP 12 REINSTALL THE MEMBR...

Страница 15: ...CB 10 TFC RO Membrane Procedure 5 micron Sediment Carbon Cartridge 50 or 75 USGPD refer to Cartridge Rated Membrane instructions 3 sump models 3 sump models x2 refer to model all models Every 12 month...

Страница 16: ...92403 10 Membrane RO 50 GPD TFC 92035 75 GPD TFC 92022 11 Housing cartridge white black 92026 12 Cartridge pre filter 5 micron 26091 13 Cartridge carbon 26081 14 Saddle drain set RO 3 8 92160 15 Clip...

Страница 17: ...14 Reverse Osmosis Drinking Water System Flow Diagram all models...

Страница 18: ...feed water TDS Contact dealer for revised product water TDS 3 Membrane life expired Replace membrane Bad tasting water 1 Taste from glass or plastic containers Contact dealer for explanation 2 Post ca...

Страница 19: ...AIR GAP TOMLINSON BISCUIT 87544 AIR GAP TOMLINSON BLACK 87547 AIR GAP TOMLINSON BRIGHT NICKEL 87548 AIR GAP TOMLINSON BRUSHED STAINLESS FINISH 87545 AIR GAP TOMLINSON POLISHED BRASS 87540 AIR GAP TOML...

Страница 20: ...t minerals or bacteria attack installation or operation contrary to our printed instructions or damage caused by hot water freezing flood fire or Act of God is not covered by this warranty In all such...