6
Installation of Filters
A. Sump #1 - Sediment Pre-filter 5 micron Cartridge
B. Sump #2 - Carbon Pre-filter Cartridge
C. Sump #3 - Carbon Post-filter Cartridge
Installation of Membrane
Important:
Keep the membrane and your hands clean in order to
avoid bacterial contamination of the membrane.
1. Disconnect the hose on the end of the membrane housing end
cap.
2. Unscrew the end-cap.
3.
Hold the membrane upside down, cut the plastic bag at the
bottom, and drain off any liquid.
4. The bottom tip of the membrane must seat firmly in the
protruding female socket inside the membrane housing.
5. Without touching the membrane, slide it into the membrane
housing and discard the plastic bag. With your thumb or the palm
of your hand, push the membrane all the way into the housing.
Important:
Do not use force, and ensure that the membrane is
not protruding from the housing.
6. Replace the membrane housing end cap and hand tighten.
7. Push the tubing back into the quick connect fitting. Ensure the
tubing is all the way in.
Connecting Components
Figure 8 - Installing membrane without
touching
Figure 7 - Front View
a. Connect the 1/4" white tube from the (90° elbow) 5 micron
pre-filter fitting to the fitting on the cold water supply line.
b. Connect the 3/8" blue tube from the (90° elbow)
granular activated carbon post-filter fitting to the quick
connect fitting on the threaded pipe on the spigot.
c. Connect the 3/8" tube from the (male tee) granular activated
carbon post-filter fitting to the fitting on the storage tank.
d.
Standard Faucet
- Connect the 1/4" red tube to
the drain fitting.
Sump #3 Sump #2 Sump #1