background image

Power Head Parts List 

Item No.

Part No.

Part Description

Quantity

B01

5056136

Screw-ST3.5×13(Hexagon with Washer)

4

B02

5056014

Bnt65 Back Cover

1

B03

5010045

Piston Stem Holder

1

A26

13000426

Screw-ST2.9×13(Large Wafer)  

1

B04

5056139

Washer-3x13

1

B05

5056005

Main Gear 

1

B06

5056083

Screw-M4x14

1

B07

5056166

Screw-ST4.2×12(Large Wafer)  

1

B08

5056141

Washer-4x12

1

B09

13111004

Washer-4x9

1

B10

5056016

Refill Regulator

1

B11

5056015

Brine Gear 

1

B12

5056089

Nut-M4

1

B13

5056095

Spring Detent

2

B14

5056001

Bnt65 Housing

1

B15

5010037

Screw-ST2.9×10

5

B16

5056504

Bnt165 Pcb

1

B17

5056500

Bnt165 Front Cover

1

5056505

Bnt165 Operation Label

1

5056506

Bnt165 Regen. Label

1

B18

5056509

Screw-ST2.9×10(CSK )

2

B19

5056082

Screw-M3×5 2

B20

5056510

Motor-12v/2rpm

1

11700005

Wire Connector

2

B21

5056045

Motor Mounting Plate

1

B22

5056501

Bnt165 Drive Gear

1

A04

5010081

Bnt65 Piston Rod

1

B23

5056002

Idler Gear

1

B24

5010031

Meter Assembly

1

5010046

Meter Strain Relief

1

B25

5056094

Spring Idler

1

B26

5056098

Motor Pin 

1

B27

5056502

Spring Retainer

1

B28

5056507

Bnt165 Power Cable

1

5056013

Bnt65 Power Strain Relief

1

B29

5056092

Ball-1/4inch

2

B30

5056503

Magnet Holder

1

B31

5010023

Magnet-

φ

3×2.7

1

B32

5056008

Bnt65 Knob

1

5056111

Bnt65 Knob Label

1

B33

5056084

Screw-ST3.5x13

1

22  

Содержание 565BM-100

Страница 1: ...gs during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown qualit...

Страница 2: ...ual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping c...

Страница 3: ...cessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat sold...

Страница 4: ...5 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Service Flow Rates Normal 2 0 gpm 3 0 gpm 5 0 gpm 6 0 gpm 7 0 gpm Peak 3 5 gpm 5 0 gpm 8 0 gpm 10 0 gpm...

Страница 5: ...s Before Starting Installation Tools Pipe and Fittings Other Materials Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modifi cation to home plum...

Страница 6: ...ut the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transformer...

Страница 7: ...ump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipmen...

Страница 8: ...hen soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also include...

Страница 9: ...Filter Installation 9...

Страница 10: ...VICE position after the RINSE cycle is complete Open the outlet valve on the bypass then open the nearest treated water fau cet and allow the water to run until clear close the tap and replace the fau...

Страница 11: ...or less frequent regenera tions This can be adjusted by the home owner to suite their individual needs with fre quencies available from 1 99 days To prevent bacterial build up in the media activated c...

Страница 12: ...re set regeneration time i e 2 00 a m To cancel press the MANUAL REGEN key again Operation During A Power Failure In the event of a power failure the valve will keep track of the time and day for 48 h...

Страница 13: ...30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass valve...

Страница 14: ...o determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on the w...

Страница 15: ...ine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank and...

Страница 16: ...8 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FILTE...

Страница 17: ...17...

Страница 18: ...A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CLIP...

Страница 19: ...Control Valve Exploded View Control Valve Exploded View 19...

Страница 20: ...A18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring 23 6 2 65 2 A23 21319006 Screw Adaptor 2 A24...

Страница 21: ...Power Head Exploded View 21...

Страница 22: ...T2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 5056510...

Страница 23: ...f central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2 Iro...

Страница 24: ...ture WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operate...