10
System Start-Up
1. Plug the valve into an approved power source.
2. When power is supplied to the control, the screen will display “WAITING PLEASE” while it
finds the service position.
3. Start an Immediate Manual Regeneration. The valve will immediately start moving to the
BACKWASH position.
4. Open the inlet on the bypass valve slightly and very slowly allow water to enter the unit.
(If the water enters too quickly it will push the carbon up into the control valve and get
plugged).
5. Once the unit has filled sufficiently that water is at least equal to the height of the top of
the media shut down the water for 15 – 20 minutes for the carbon to soak. Unplug the
power cable. After the carbon has soaked for the recommended time continue by plug-
ging the power cable back in.
6. Turn the water back on slowly to backwash until water runs clear to drain.
7. Press any button to advance to the RINSE position. Check the drain line flow. Allow the
water to run for 3-4 minutes or until the water is clear.
8. The valve will automatically advance to the SERVICE position after the RINSE cycle is
complete. Open the outlet valve on the bypass, then open the nearest treated water fau-
cet and allow the water to run until clear, close the tap and replace the faucet screen.
9. Program time, date, and number of days between regenerations into controller using Pro-
gramming Instructions
Note : Carbon filters only:
Once the unit has filled sufficiently that water is at least equal to the height of the media
shut down the water for 15 – 20 minutes for the carbon to soak.
After the carbon has soaked for the recommended time continue with installation instruc-
tions.
Additional information for Non backwashing carbon filter.
After soaking, remove the aerator screen from the nearest faucet, run water at this faucet
until all fines (black) is gone from the water.
Start-up Instructions
Key Pad Configuration
SETTINGS
This
function
is
to
enter
the
basic
set
up
information
required
at
the
time
of
installation.
MANUAL
REGEN
This
button
has
two
functions.
The
first
is
to
initiate
an
immediate
or
delayed
manual
regeneration.
The
second
is
while
in
programming
mode,
pressing
this
key
allows
the
user
to
change
the
value
of
each
setting.
DOWN
/
UP
Increase
or
decrease
the
value
of
the
settings
while
in
the
program
‐
ming
mode.