background image

Specifications 



Continuous operation at flow rates greater than the ser-
vice flow rate may affect capacity and efficiency per-
formance. 



The manufacturer reserves the right to make product 
improvements which may deviate from the specifications 
and descriptions stated herein, without obligation to 

change previously manufactured products or to note the 
change. 



Peak flow rates are intended for intermittent use only 
and are for residential application only 



At the stated service flow rates, the pressure drop 
through these devices will not exceed 15 psig 

Service

 

Flow

 

Rates

          

Normal

4.0

 

gpm

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

12.0

 

gpm

          

Peak

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

12.0

 

gpm

15.0

 

gpm

Micron

 

Rating

15

20

 

micron

15

20

 

micron

15

20

 

micron

15

20

 

micron

15

20

 

micron

Backwash

 

Flow

 

Rate

4.0

 

gpm

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

14.0

 

gpm

Filter

 

Media

 

Volume

 ‐ 

Cubic

 

Feet

0.75

 

ft

3

1.0

 

ft

3

1.5

 

ft

3

2.0

 

ft

3

3.0

 

ft

3

Filter

 

Tank

 

Size

8x44

9x48

10x54

12x52

14x65

Tank

 

Jacket

 

/

 

Media

 

Loaded

Yes

Yes

Yes

No

No

Shipping

 

Weight

79

 

lbs

118

 

lbs

144

 

lbs

198

 

lbs

342

 

lbs

Service

 

Flow

 

Rates

          

Normal

4.0

 

gpm

5.0

 

gpm

7.0

 

gpm

10

 

gpm

12.0

 

gpm

          

Peak

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

12.0

 

gpm

15.0

 

gpm

Backwash

 

Flow

 

Rate

3.5

 

gpm

4.0

 

gpm

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

Filter

 

Media

 

Volume

 ‐ 

Cubic

 

Feet

0.75

 

ft

3

1.0

 

ft

3

1.5

 

ft

3

2.0

 

ft

3

3.0

 

ft

3

Filter

 

Tank

 

Size

8x44

9x48

10x54

12x52

14x65

Tank

 

Jacket

 

/

 

Media

 

Loaded

Yes

Yes

Yes

No

No

Shipping

 

Weight

50

 

lbs

60

 

lbs

78

 

lbs

95

 

lbs

138

 

lbs

Service

 

Flow

 

Rates

          

Normal

2.0

 

gpm

3.0

 

gpm

5.0

 

gpm

6.0

 

gpm

7.0

 

gpm

          

Peak

3.5

 

gpm

5.0

 

gpm

8.0

 

gpm

10.0

 

gpm

12.0

 

gpm

Backwash

 

Flow

 

Rate

3.5

 

gpm

4.0

 

gpm

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

Filter

 

Media

 

Volume

 ‐ 

Cubic

 

Feet

0.75

 

ft

3

1.0

 

ft

3

1.5

 

ft

3

2.0

 

ft

3

3.0

 

ft

3

Filter

 

Tank

 

Size

8x44

9x48

10x54

12x52

14x65

Tank

 

Jacket

 

/

 

Media

 

Loaded

Yes

Yes

Yes

No

No

Shipping

 

Weight

93

 

lbs

120

 

lbs

164

 

lbs

207

 

lbs

330

 

lbs

Service

 

Flow

 

Rates

          

Normal

4.0

 

gpm

5.0

 

gpm

8.0

 

gpm

10.0

 

gpm

          

Peak

7.0

 

gpm

8.0

 

gpm

10.0

 

gpm

12

 

gpm

Micron

 

Rating

3

5

 

micron

3

5

 

micron

3

5

 

micron

3

5

 

micron

Backwash

 

Flow

 

Rate

5.0

 

gpm

7.0

 

gpm

10.0

 

gpm

14.0

 

gpm

Filter

 

Media

 

Volume

 ‐ 

Cubic

 

Feet

0.75

 

ft

3

1.0

 

ft

3

1.5

 

ft

3

2.0

 

ft

3

Filter

 

Tank

 

Size

8x44

9x48

10x54

12x52

Tank

 

Jacket

Yes

Yes

Yes

No

Shipping

 

Weight

90

 

lbs

135

 

lbs

205

 

lbs

255

 

lbs

ALL

 

FILTERS

Plumbing

 

Connections

Electrical

 

Requirements

Water

 

Temperature

Water

 

Pressure

3/4"

 

(Optional

 

1")

Input

 

120V

 

60

 

Hz

 ‐ 

Output

 

12V

 

650mA

Min

 

39

  ‐ 

Max.

 

100

 

degrees

 

Fahrenheit

Min.

 

20

 ‐ 

Max.

 

125

 

psi

48NEX

75

585NEX

100

585NEX

150

585NEX

200

485NU

75

585NU

100

585NU

150

585NU

200

585NU

300

585TO

75

585TO

100

585TO

150

585TO

200

585TO

300

585MM

75

585MM

100

585MM

150

585MM

200

585MM

300

Specifications

Specifications

Specifications

Specifications

565BM-75         565BM-100          565BM-150        565BM-200        565BM-300 

785TO-75           785TO-100        785TO-150        785TO-200         785TO-300 

785NU75           785NU-100        785NU-150        785NU-200         785NU-300 

785NEX75         785NEX-100       785NEX-150     785NEX-200         
785NU-300 

 

4  

Содержание 565BM-100

Страница 1: ...gs during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown qualit...

Страница 2: ...ual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping c...

Страница 3: ...cessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat sold...

Страница 4: ...5 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Service Flow Rates Normal 2 0 gpm 3 0 gpm 5 0 gpm 6 0 gpm 7 0 gpm Peak 3 5 gpm 5 0 gpm 8 0 gpm 10 0 gpm...

Страница 5: ...s Before Starting Installation Tools Pipe and Fittings Other Materials Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modifi cation to home plum...

Страница 6: ...ut the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transformer...

Страница 7: ...ump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipmen...

Страница 8: ...hen soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also include...

Страница 9: ...Filter Installation 9...

Страница 10: ...VICE position after the RINSE cycle is complete Open the outlet valve on the bypass then open the nearest treated water fau cet and allow the water to run until clear close the tap and replace the fau...

Страница 11: ...or less frequent regenera tions This can be adjusted by the home owner to suite their individual needs with fre quencies available from 1 99 days To prevent bacterial build up in the media activated c...

Страница 12: ...re set regeneration time i e 2 00 a m To cancel press the MANUAL REGEN key again Operation During A Power Failure In the event of a power failure the valve will keep track of the time and day for 48 h...

Страница 13: ...30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass valve...

Страница 14: ...o determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on the w...

Страница 15: ...ine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank and...

Страница 16: ...8 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FILTE...

Страница 17: ...17...

Страница 18: ...A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CLIP...

Страница 19: ...Control Valve Exploded View Control Valve Exploded View 19...

Страница 20: ...A18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring 23 6 2 65 2 A23 21319006 Screw Adaptor 2 A24...

Страница 21: ...Power Head Exploded View 21...

Страница 22: ...T2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 5056510...

Страница 23: ...f central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2 Iro...

Страница 24: ...ture WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operate...

Отзывы: