background image

Maintenance 

Care of Your System 

To retain the attractive appearance of your new water filter, clean occasionally with mild 

soap solution.  Do not use abrasive cleaners, ammonia or solvents.  Never subject your sof-
tener to freezing or to temperatures above 100°F. 

Maintenance of your new water filter requires very little time or effort but it is essential. 

Regular maintenance will ensure many years of efficient and trouble-free operation. 
 

1. Periodically make sure your pump is performing satisfactorily to ensure sufficient water is 

available for backwashing the filter. 

2. Periodically test your raw and filtered water to ensure conditions are still the same for 

your original settings and that the unit is working they way it is intended to.  Water test-
ing is often the best way to determine when the filter media will require replacement. 

3. Periodically check that the drain line is clear and free from any obstructions. 

NE - Neutralizing Filter 

- the media bed in a neutralizing filter is slowly dissolved and has 

to be replaced. The frequency of replacement varies, depending on water quality - consult 
your dealer to determine the expected life of your media bed. 

 

AC - Taste and Odor Filter 

- under normal operating conditions the effective life of the 

filter media is approximately one to three years, depending on the water quality, after 

which, taste and odor problems may return. When this happens, contact your dealer for a 
replacement media bed. 

 

MM - Sediment and Turbidity Filter 

- under normal operating conditions, the media 

should never need to be replaced. However, if you experience pressure loss and cannot cor-

rect it with a manual regeneration, your media bed may need replacing - contact your 
dealer. 

 

Replacing the Media Bed 

Check to ensure all media parts are received. 

 
The first step in replacing the media bed is to shut off the water supply to the filter. Then 

place the unit into the backwash position to release any pressure in the lines.  At this point, 
you must disconnect the plumbing from the inlet and outlet.  Then unscrew the control 

valve from the fibreglass tank.  Once this has been done, remove the distributor tube.  Then 

you can remove the filter media and two types of gravel from the tank.  The quickest way to 
do this is by simply tipping the tank upside down into a large drum or pail. The tank must 

be rinsed out completely and have no media or gravel left in it at all. 

Installation & Replacement Filter Media Pak 

14  

Содержание 565BM-100

Страница 1: ...gs during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown qualit...

Страница 2: ...ual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping c...

Страница 3: ...cessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat sold...

Страница 4: ...5 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Service Flow Rates Normal 2 0 gpm 3 0 gpm 5 0 gpm 6 0 gpm 7 0 gpm Peak 3 5 gpm 5 0 gpm 8 0 gpm 10 0 gpm...

Страница 5: ...s Before Starting Installation Tools Pipe and Fittings Other Materials Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modifi cation to home plum...

Страница 6: ...ut the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transformer...

Страница 7: ...ump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipmen...

Страница 8: ...hen soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also include...

Страница 9: ...Filter Installation 9...

Страница 10: ...VICE position after the RINSE cycle is complete Open the outlet valve on the bypass then open the nearest treated water fau cet and allow the water to run until clear close the tap and replace the fau...

Страница 11: ...or less frequent regenera tions This can be adjusted by the home owner to suite their individual needs with fre quencies available from 1 99 days To prevent bacterial build up in the media activated c...

Страница 12: ...re set regeneration time i e 2 00 a m To cancel press the MANUAL REGEN key again Operation During A Power Failure In the event of a power failure the valve will keep track of the time and day for 48 h...

Страница 13: ...30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass valve...

Страница 14: ...o determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on the w...

Страница 15: ...ine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank and...

Страница 16: ...8 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FILTE...

Страница 17: ...17...

Страница 18: ...A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CLIP...

Страница 19: ...Control Valve Exploded View Control Valve Exploded View 19...

Страница 20: ...A18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring 23 6 2 65 2 A23 21319006 Screw Adaptor 2 A24...

Страница 21: ...Power Head Exploded View 21...

Страница 22: ...T2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 5056510...

Страница 23: ...f central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2 Iro...

Страница 24: ...ture WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operate...

Отзывы: