background image

13

Ref.  Description

SPX50 Part # Qty.

1

Cap, Cord

22407C600

1

2

Connector

12672A001

3

Tube, Plastic  x 1-1/4" Lg.

10649A102

2

4

Screw, Cap 5/16 x 1-1/4" Lg.

19100A012

8

5

O-Ring, 4-1/2" x 4-1/4" x 1/8"

05876A122

1

6

Cap, Upper Bearing

21570B100

1

7

O-Ring, 4-7/8" x 4-5/8" x 1/8"

05876A123

1

8

Plug, Pipe 1/4" NPT

05022A054

2

9

Screw, Mach. #10 x 1/2" Lg.

05434A034

1

10

Washer, Lock

06107A015

1

11

Screw, Mach. 5/16 x 1" Lg. (SX50)

07597A017

2

11

Screw, Mach. 5/16 x 1" Lg. (SX50H)

07597A017

6

12

Housing w/Stator

21571D150K

1

Housing, Motor

21571D100

Stator Only

21656C103

13

Oil, Transformer (1 gal. can)

1.06 gal.

14

Washer, Spring

19331A005

2

15

Bearing, Ball (upper)

08565A013

1

16

Ring, Retaining

11816A006

1

17

Rotor w/Shaft

26859C101

1

18

Bearing, Ball (lower)

08565A018

1

19

Housing, Upper Seal

21574D100

1

20

Seal, Shaft

21576A010

2

21

Ring, Retaining

12588A006

1

22

Electrode w/Resistor

22578A003

1

23

O-Ring, 6-1/8" x 5-7/8" x 1/8"

05876A125

2

24

Ferrule, Rubber

22579A000

1

25

Plug, Special

21577A000

1

26

Housing, Lower Seal

21578C115

1

27

Screw, Cap 5/16 x 1" Lg.

06106A008

4

28

Case, Volute

26226D012

1

29

Screw, Cap 1/4 x 1" Lg.

19099A012

3

30

Impeller, Recessed

21663C010

1

31

Nut, Jam

19109A070

1

32

Screw, Set

05013A027

2

SPX50

Parts List  

Содержание SPX50

Страница 1: ...ion Proof Pumps SPX50 SPX50H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...e power source before handling or servicing 7 Any wiring to be done on pumps should be done by a qualified electrician 8 Never operate a pump with a power cord that has frayed or brittle insulation 9 Never let cords or plugs lie in water 10 Never handle connected power cords with wet hands Pumps 11 Pump builds up heat and pressure during operation allow time for pump to cool before handling or ser...

Страница 3: ...rd cord grip and internally through the use of a dielectric potting resin surrounding the electrical wires Internal connection wiring diagrams are shown in page 6 All of the pump fasteners and shafts are made from corrosion resistant stainless steel while the pump castings are made of ASTM A 48 Class 30 cast iron and the multivane vortex impellers are made from Class 20 cast iron General Installat...

Страница 4: ...n explosion proof pump the reading should be above 30 000 ohms If the measured values are below those indicated above the pump may have a lower seal failure and require service On the Hydromatic explosion proof control panels the seal leak test switch tests the seal leak circuit continuity When pushed the seal leak test bulb should light If the test bulb does not light it means either the wiring c...

Страница 5: ...ns All electrical wiring must be in accordance with local code and only qualified electrician should make the installations Complete wiring diagrams are included for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause failure of the pump control panel or personal i...

Страница 6: ...e Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft Place the seal over the shaft Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational...

Страница 7: ... may be damaged by lightning 3 Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box CONDITION Pump is noisy and pump rate is low PROBABLE CAUSE 1 Impeller may be partially clogged with some foreign objects causing noise and overload on the motor CONDITION Grease and solids have accumulated around pump and will not pum...

Страница 8: ...8 Pump Wiring Diagrams ...

Страница 9: ...9 Pump Wiring Schematic WIRING SCHEMATIC FOR 230V 1Ø SIMPLEX SYSTEM ...

Страница 10: ...10 Performance Curves ...

Страница 11: ...51 5 13 32 137 2 NPT 9 1 32 229 3 19 32 91 3 31 32 101 239 9 13 32 4 102 4 102 9 5 16 236 241 9 15 32 NPT 1 1 2 4 13 16 122 1 31 32 50 20 508 SPX50 Dimensions in mm SPX50H Dimensions in mm SPX50 SPX50H Dimensional Data ...

Страница 12: ...ing Motor 21571D100 12 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 0856A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A...

Страница 13: ...ing Motor 21571D100 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 08565A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A12...

Страница 14: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 15: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 16: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: