Pump
Information

Pump Models:

These instructions cover the
installation and service of the
Hydromatic SPX50 and SPX50H
series submersible sump pumps.
The models are CSA listed
explosion-proof for hazardous
wastewater locations Group 1,
Div. 1, Class D.

Motor HP & Voltages:  

The SPX50/SPX50H sump
pumps are offered in single phase.
Voltages will vary according to
the application and can be seen in
the tables in this manual.

Electrical Controls:

All of these pump models must be
used with a control panel.
Hydromatic built control panels
are designed to supply the correct
electrical controls and motor
starting equipment and include
the circuitry for moisture and heat
sensors. It is recommended that a
Hydromatic built control panel be
used so that all warranties apply.

General Construction:

The SPX50/SPX50H motor
construction is designed to 
meet CSA

requirements for

Group 1, Div. 1, Class D
wastewater applications. These
models are certified and
nameplated with this approval.  A
cross-sectional view of the
internal workings of the pumps
can be seen on pages 12 & 13.
The motor chamber and seal
chamber are filled with a high
dielectric type oil for improved
lubrication and heat transfer of
the bearings and motor.  Since the

bearings have been designed for
50,000 hours of life, the oil
should never require replacement
under normal operating 
conditions.  An air space above
the oil level in both the seal and
motor chambers is provided to
allow for the expansion of the oil
when at operating temperature.
The power and control lines are
sealed and strain relieved on the
outside entrance with a standard
cord grip, and internally through
the use of a dielectric potting
resin surrounding the electrical
wires.

Internal connection wiring
diagrams are shown in page 6.
All of the pump fasteners and
shafts are made from
corrosion-resistant stainless steel,
while the pump castings are made
of ASTM A-48 Class 30 cast iron,
and the multivane vortex
impellers are made from Class 20
cast iron.

General Installation: 

Various configurations and
methods of plumbing this series
of sump pumps may be used.

NOTE: If the SPX50 and
SPX50H explosion-proof pumps
are used in conjunction with a
rail lift-out system, it must be
a UL

or

CSA

approved

nonsparking, explosion-proof
system.

IMPORTANT: If the following
guidelines are not followed, the
UL explosion-proof approval is
void.

Explosion-Proof Service:  

These pumps are to be used
for handling contaminated septic
tank effluent, sewage, and storm
water only. The SPX50/SPX50H is
CSA approved (Group 1, Division
1, Class D) to handle a wide
variety of pollutants, including
gas and oil. Do not use in other
hazardous locations. These
motors must be repaired 
and serviced only at a Hydromatic
authorized service center or at 
the Hydromatic factory. Any
unauthorized field repair voids
warranty and the explosion-proof
rating.

CAUTION: After the pump is
installed and wastewater has
entered the basin, there is
danger.  Sewage water gives 
off methane and hydrogen 
sulfide gases, which are 
poisonous.  Never enter a wet
well unless the cover is open for
a sufficient period of time to
allow fresh air into the basin. It
is recommended that a man in
the basin have a harness on 
with a rope to the surface, so
that he can be pulled out in 
case of asphyxiation. It is for
this reason that Hydromatic
recommends using the rail
lift-out system so that no
service is required inside 
the basin.

Содержание SPX50

Страница 1: ...ion Proof Pumps SPX50 SPX50H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...e power source before handling or servicing 7 Any wiring to be done on pumps should be done by a qualified electrician 8 Never operate a pump with a power cord that has frayed or brittle insulation 9 Never let cords or plugs lie in water 10 Never handle connected power cords with wet hands Pumps 11 Pump builds up heat and pressure during operation allow time for pump to cool before handling or ser...

Страница 3: ...rd cord grip and internally through the use of a dielectric potting resin surrounding the electrical wires Internal connection wiring diagrams are shown in page 6 All of the pump fasteners and shafts are made from corrosion resistant stainless steel while the pump castings are made of ASTM A 48 Class 30 cast iron and the multivane vortex impellers are made from Class 20 cast iron General Installat...

Страница 4: ...n explosion proof pump the reading should be above 30 000 ohms If the measured values are below those indicated above the pump may have a lower seal failure and require service On the Hydromatic explosion proof control panels the seal leak test switch tests the seal leak circuit continuity When pushed the seal leak test bulb should light If the test bulb does not light it means either the wiring c...

Страница 5: ...ns All electrical wiring must be in accordance with local code and only qualified electrician should make the installations Complete wiring diagrams are included for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause failure of the pump control panel or personal i...

Страница 6: ...e Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft Place the seal over the shaft Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational...

Страница 7: ... may be damaged by lightning 3 Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box CONDITION Pump is noisy and pump rate is low PROBABLE CAUSE 1 Impeller may be partially clogged with some foreign objects causing noise and overload on the motor CONDITION Grease and solids have accumulated around pump and will not pum...

Страница 8: ...8 Pump Wiring Diagrams ...

Страница 9: ...9 Pump Wiring Schematic WIRING SCHEMATIC FOR 230V 1Ø SIMPLEX SYSTEM ...

Страница 10: ...10 Performance Curves ...

Страница 11: ...51 5 13 32 137 2 NPT 9 1 32 229 3 19 32 91 3 31 32 101 239 9 13 32 4 102 4 102 9 5 16 236 241 9 15 32 NPT 1 1 2 4 13 16 122 1 31 32 50 20 508 SPX50 Dimensions in mm SPX50H Dimensions in mm SPX50 SPX50H Dimensional Data ...

Страница 12: ...ing Motor 21571D100 12 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 0856A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A...

Страница 13: ...ing Motor 21571D100 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 08565A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A12...

Страница 14: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 15: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 16: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: