background image

Item # W-03-415  Rev. 12/15/11

Part # 5625-415-1

– Your Authorized Local Distributor –

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 888-957-8677  Fax: 888-840-7867

www.hydromatic.com

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

© 2011 Hydromatic

®

Ashland, Ohio. All Rights Reserved.

LIMITED WARRANTY

HYDROMATIC warrants to the original consumer purchaser (“Purchaser” or “You”) of HYDROMATIC Sump
Pumps, Effluent Pumps, Sewage Pumps (other than 2-1/2"), and Package Systems, that they will be free from
defects in material and workmanship for the Warranty Period of 36 months from date of manufacture.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence,
misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a
three phase motor with single phase power through a phase converter will void the warranty. Note also that 
three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of
the recommended size or the warranty is void.

Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products
(at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and
must request warranty service through the installing dealer as soon as a problem is discovered. No request
for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump Pumps, Filtered Effluent
Pumps, Grinder Pumps, and 2-1/2" Sewage Pumps are warranted for a period of 12 months from date of
purchase or 18 months from date of manufacture, whichever comes first.

HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES
SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on
the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty
gives You specific legal rights and You may also have other rights which vary from state to state.

This warranty supersedes and replaces all previous warranty publications.

HYDROMATIC

740 East 9th Street, Ashland, OH  44805

Phone: 888-957-8677  •  Fax: 888-840-7867  •  Web Site: http://www.hydromatic.com

Содержание SPX50

Страница 1: ...ion Proof Pumps SPX50 SPX50H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...e power source before handling or servicing 7 Any wiring to be done on pumps should be done by a qualified electrician 8 Never operate a pump with a power cord that has frayed or brittle insulation 9 Never let cords or plugs lie in water 10 Never handle connected power cords with wet hands Pumps 11 Pump builds up heat and pressure during operation allow time for pump to cool before handling or ser...

Страница 3: ...rd cord grip and internally through the use of a dielectric potting resin surrounding the electrical wires Internal connection wiring diagrams are shown in page 6 All of the pump fasteners and shafts are made from corrosion resistant stainless steel while the pump castings are made of ASTM A 48 Class 30 cast iron and the multivane vortex impellers are made from Class 20 cast iron General Installat...

Страница 4: ...n explosion proof pump the reading should be above 30 000 ohms If the measured values are below those indicated above the pump may have a lower seal failure and require service On the Hydromatic explosion proof control panels the seal leak test switch tests the seal leak circuit continuity When pushed the seal leak test bulb should light If the test bulb does not light it means either the wiring c...

Страница 5: ...ns All electrical wiring must be in accordance with local code and only qualified electrician should make the installations Complete wiring diagrams are included for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause failure of the pump control panel or personal i...

Страница 6: ...e Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft Place the seal over the shaft Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational...

Страница 7: ... may be damaged by lightning 3 Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box CONDITION Pump is noisy and pump rate is low PROBABLE CAUSE 1 Impeller may be partially clogged with some foreign objects causing noise and overload on the motor CONDITION Grease and solids have accumulated around pump and will not pum...

Страница 8: ...8 Pump Wiring Diagrams ...

Страница 9: ...9 Pump Wiring Schematic WIRING SCHEMATIC FOR 230V 1Ø SIMPLEX SYSTEM ...

Страница 10: ...10 Performance Curves ...

Страница 11: ...51 5 13 32 137 2 NPT 9 1 32 229 3 19 32 91 3 31 32 101 239 9 13 32 4 102 4 102 9 5 16 236 241 9 15 32 NPT 1 1 2 4 13 16 122 1 31 32 50 20 508 SPX50 Dimensions in mm SPX50H Dimensions in mm SPX50 SPX50H Dimensional Data ...

Страница 12: ...ing Motor 21571D100 12 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 0856A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A...

Страница 13: ...ing Motor 21571D100 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 08565A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A12...

Страница 14: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 15: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 16: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: