Pump
Troubleshooting

CONDITION

Red light comes on at control box.

PROBABLE CAUSE

This indicates some water has leaked past the lower seal and has entered the  seal
chamber and made contact with the electrode probe.  Pump must be
removed for replacement of lower seal.  This preventive repair will save an 
expensive motor.

CONDITION

Overload trips at control box and alarm buzzer or flashing red light comes on due
to high water level in basin.

PROBABLE CAUSE

1. Push in on red reset button to reset overload.  If overload trips again after short 

run, pump has some damage and must be removed from basin for 
checking.

2. Trouble may be from clogged impeller causing motor to overload or could be 

from failed motor.

3. Trouble may be from faulty component in control box. Always check

control box before removing pump.

CONDITION

Yellow run light stays on continuously.

PROBABLE CAUSE

1. Indicates H-O-A switch may be in the Hand position.
2. Level control switch may have failed, causing pump to continue to operate

when water is below lower control.

3. Impeller may be partially clogged, causing pump to operate at very reduced

capacity.

4. Gate valve or check valve may be clogged, causing low pump flow.
5. Pump may be air logged.

CONDITION

Circuit breaker trips.

PROBABLE CAUSE

1. Reset breaker by pushing completely down on handle then back to On

position. If breaker trips again in few seconds, it indicates excessive
load probably caused by a short in the motor or control box.  Check out 
instructions given with control box before pulling pump.

2. If this condition happens after an electrical storm, motor or control box 

may be damaged by lightning.

3. Resistance reading of the motor with lead wires disconnected from the

control box can determine if trouble is in motor or control box.

CONDITION

Pump is noisy and pump rate is low.

PROBABLE CAUSE

1. Impeller may be partially clogged with some foreign objects, causing noise 

and overload on the motor.

CONDITION

Grease and solids have accumulated around pump and will not pump out 
of basin.

PROBABLE CAUSE

1. Lower control switch may be set too high.
2. Run pump on Hand operation for several minutes with small amount of

water running into basin to clean out solids and grease.  This allows pump
to break suction and surge which will break up the solids.  If level switch
is set properly, this condition generally will not occur.

3. Trash and grease may have accumulated around floats, causing pump to 

operate erratically.

Checking for

Moisture in

Motor:  

Use an ohmmeter or a Megger
and set on highest scale.
Readings on the large power cord
between any of the conductors
red, black or white to the green
conductor or to the motor housing
should be greater than 1,000,000
ohms (megohm). 
A motor will probably run with a
lower reading, but if the pump is
out of service and the value of the 
reading is below 1,000,000 ohms
(1 megohm), the motor housing
and stator should be removed and
baked in a drying oven at 220°F.
This service work should be done
only at an authorized service
station.

NOTE: Readings should be
taken with the line leads 
disconnected from the control
panel. 

Resistance of Windings:  

Every motor winding has a fixed
resistance.  The windings must
check close to the values given in
the tables to operate properly.

See the motor electrical data
chart.  Use an ohmmeter and set
to the one ohm scale.  Read the
resistance with the motor leads
disconnected from the pump
control panel.

Содержание SPX50

Страница 1: ...ion Proof Pumps SPX50 SPX50H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...e power source before handling or servicing 7 Any wiring to be done on pumps should be done by a qualified electrician 8 Never operate a pump with a power cord that has frayed or brittle insulation 9 Never let cords or plugs lie in water 10 Never handle connected power cords with wet hands Pumps 11 Pump builds up heat and pressure during operation allow time for pump to cool before handling or ser...

Страница 3: ...rd cord grip and internally through the use of a dielectric potting resin surrounding the electrical wires Internal connection wiring diagrams are shown in page 6 All of the pump fasteners and shafts are made from corrosion resistant stainless steel while the pump castings are made of ASTM A 48 Class 30 cast iron and the multivane vortex impellers are made from Class 20 cast iron General Installat...

Страница 4: ...n explosion proof pump the reading should be above 30 000 ohms If the measured values are below those indicated above the pump may have a lower seal failure and require service On the Hydromatic explosion proof control panels the seal leak test switch tests the seal leak circuit continuity When pushed the seal leak test bulb should light If the test bulb does not light it means either the wiring c...

Страница 5: ...ns All electrical wiring must be in accordance with local code and only qualified electrician should make the installations Complete wiring diagrams are included for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause failure of the pump control panel or personal i...

Страница 6: ...e Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft Place the seal over the shaft Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational...

Страница 7: ... may be damaged by lightning 3 Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box CONDITION Pump is noisy and pump rate is low PROBABLE CAUSE 1 Impeller may be partially clogged with some foreign objects causing noise and overload on the motor CONDITION Grease and solids have accumulated around pump and will not pum...

Страница 8: ...8 Pump Wiring Diagrams ...

Страница 9: ...9 Pump Wiring Schematic WIRING SCHEMATIC FOR 230V 1Ø SIMPLEX SYSTEM ...

Страница 10: ...10 Performance Curves ...

Страница 11: ...51 5 13 32 137 2 NPT 9 1 32 229 3 19 32 91 3 31 32 101 239 9 13 32 4 102 4 102 9 5 16 236 241 9 15 32 NPT 1 1 2 4 13 16 122 1 31 32 50 20 508 SPX50 Dimensions in mm SPX50H Dimensions in mm SPX50 SPX50H Dimensional Data ...

Страница 12: ...ing Motor 21571D100 12 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 0856A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A...

Страница 13: ...ing Motor 21571D100 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 08565A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A12...

Страница 14: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 15: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 16: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: