Thank you for purchasing your
Hydromatic

®

pump. To help

ensure years of trouble-free 
operation, please read the 
following manual carefully.

Before Operation: 

Reasonable care and safe methods
should be practiced. Check 
local codes and requirements
before installation.

Attention: 

This manual contains important
information for the safe use of
this product.  Read this manual
completely before using this
product and refer to it often for
continued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MANUAL.  Keep it
in a safe place so that you may
refer to it often.

WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use 
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.

1. Most accidents can be avoided

by using COMMON SENSE.

2. Read the operation and

maintenance instructions
manual supplied with the
pump.

3. Do not wear loose clothing

that can become entangled 
in the impeller or other 
moving parts.

4. This pump is designed to

handle materials that could
cause illness or disease
through direct exposure.  Wear
adequate protective clothing
when working on the pump 
or piping.

Electrical:

5. To reduce the risk of 

electrical shock, pump must
be properly grounded in
accordance with the National
Electric Code and all 
applicable state and local
codes and ordinances.

6. To reduce risk of electrical

shock, disconnect the pump
from the power source before
handling or servicing.

7. Any wiring to be done on

pumps should be done by a
qualified electrician.

8. Never operate a pump with a

power cord that has frayed or
brittle insulation.

9. Never let cords or plugs lie in

water.

10. Never handle connected

power cords with wet hands.

Pumps:

11. Pump builds up heat and

pressure during operation;
allow time for pump to cool
before handling or servicing.

12. Only qualified personnel

should install, operate or
repair pump.

13. Keep clear of suction and

discharge openings.  DO NOT
insert fingers in pump with
power connected.

General
Information

Pump
Introduction

14. Do not pump hazardous

material not recommended for
pump Group 1, Div. 1, Class D
(flammable, caustic, etc.).

15. Make sure lifting handles are

securely fastened each time
before lifting.

16. Do not lift pump by the 

power cord.

17. Do not exceed manufacturer’s

recommendation for maximum
performance, as this could
cause the motor to overheat.

18. Secure the pump in its

operating position so it cannot
tip over, fall or slide.

19. Keep hands and feet away

from impeller when power 
is connected.

20. Submersible sump pumps

are not approved for use in
swimming pools, recreational
water installations, decorative 
fountains or any installation
where human contact with the
pumped fluid is common.

21. Do not operate pump without

safety devices in place.

22. For hazardous locations, use

pumps that are listed and
classified for such locations.

IMPORTANT: Hydromatic is not
responsible for losses, injury 
or death resulting from a 
failure to observe these safety
precautions, misuse or abuse 
of pumps or equipment.

Содержание SPX50

Страница 1: ...ion Proof Pumps SPX50 SPX50H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...e power source before handling or servicing 7 Any wiring to be done on pumps should be done by a qualified electrician 8 Never operate a pump with a power cord that has frayed or brittle insulation 9 Never let cords or plugs lie in water 10 Never handle connected power cords with wet hands Pumps 11 Pump builds up heat and pressure during operation allow time for pump to cool before handling or ser...

Страница 3: ...rd cord grip and internally through the use of a dielectric potting resin surrounding the electrical wires Internal connection wiring diagrams are shown in page 6 All of the pump fasteners and shafts are made from corrosion resistant stainless steel while the pump castings are made of ASTM A 48 Class 30 cast iron and the multivane vortex impellers are made from Class 20 cast iron General Installat...

Страница 4: ...n explosion proof pump the reading should be above 30 000 ohms If the measured values are below those indicated above the pump may have a lower seal failure and require service On the Hydromatic explosion proof control panels the seal leak test switch tests the seal leak circuit continuity When pushed the seal leak test bulb should light If the test bulb does not light it means either the wiring c...

Страница 5: ...ns All electrical wiring must be in accordance with local code and only qualified electrician should make the installations Complete wiring diagrams are included for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Megger after the connections are made This is important as one grounded wire can cause failure of the pump control panel or personal i...

Страница 6: ...e Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft Place the seal over the shaft Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational...

Страница 7: ... may be damaged by lightning 3 Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box CONDITION Pump is noisy and pump rate is low PROBABLE CAUSE 1 Impeller may be partially clogged with some foreign objects causing noise and overload on the motor CONDITION Grease and solids have accumulated around pump and will not pum...

Страница 8: ...8 Pump Wiring Diagrams ...

Страница 9: ...9 Pump Wiring Schematic WIRING SCHEMATIC FOR 230V 1Ø SIMPLEX SYSTEM ...

Страница 10: ...10 Performance Curves ...

Страница 11: ...51 5 13 32 137 2 NPT 9 1 32 229 3 19 32 91 3 31 32 101 239 9 13 32 4 102 4 102 9 5 16 236 241 9 15 32 NPT 1 1 2 4 13 16 122 1 31 32 50 20 508 SPX50 Dimensions in mm SPX50H Dimensions in mm SPX50 SPX50H Dimensional Data ...

Страница 12: ...ing Motor 21571D100 12 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 0856A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A...

Страница 13: ...ing Motor 21571D100 Stator Only 21656C103 13 Oil Transformer 1 gal can 1 06 gal 14 Washer Spring 19331A005 2 15 Bearing Ball upper 08565A013 1 16 Ring Retaining 11816A006 1 17 Rotor w Shaft 26859C101 1 18 Bearing Ball lower 08565A018 1 19 Housing Upper Seal 21574D100 1 20 Seal Shaft 21576A010 2 21 Ring Retaining 12588A006 1 22 Electrode w Resistor 22578A003 1 23 O Ring 6 1 8 x 5 7 8 x 1 8 05876A12...

Страница 14: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 15: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 16: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: