Appendix 1: OPS
®
Explanation Guide
50-11 Series OPS
®
Gravity
This OPS
®
provides total control of the aerobic unit
including air pump and alarms. Other features include
separate disconnect switch (which cuts off power to
all electrical components) with an optional lockout
feature. It requires a single circuit 120 volt / 20 amp
feed.
Typical Applications Include:
• Direct Discharge
• Gravity Flow to Gravel Drain Fields
• Gravity Flow to Leaching Chambers or any disposal
method where a pump is not required.
Equipment Included:
1
– Air Pump
1
– Polyethylene OPS
®
Base & Enclosure
1
– Electrical Control Panel
Small Components Include:
Wiring harnesses, electrical connectors, liquid tight
compression fittings, air tubing, shraeder valve,
audible alarm, visual alarm, and various other
components which provide for integration of the
OPS
®
.
50-20 Series
OPS
®
On Demand
This OPS
®
provides total control of the aerobic unit
and pump tank including air pump, water pump and
alarms. Other features include two-branch circuit
breakers, separate disconnect switch (which cuts off
power to all electrical components) with an optional
lockout feature. It requires a single circuit 120 volt /
30 amp feed.
Typical Applications Include:
• Spray Irrigation
• Pumping to Gravel Drain Fields
• Pumping to Low Pressure Dosing Systems
• Pumping to Leaching Chambers or any disposal
method requiring a pump where timed dosing is not
required.
Equipment Included:
1
– Air Pump
1
– Polyethylene OPS
®
Base & Enclosure
1
– Electrical Control
Floats Switches Required:
1
– Water Pump On/Off Float
1
– Pump Tank High Level Alarm Float
Small Components Include:
Wiring harnesses, electrical connectors, liquid tight
compression fittings, air tubing, shraeder valve,
audible alarm, visual alarm, and various other
components which provide for integration of the
OPS
®
.
50-30 Series OPS
®
24 Hr. Time
This OPS
®
provides total control of the aerobic unit
and pump tank including air pump, water pump and
alarms. Other features include two-branch circuit
breakers, separate disconnect switch (which cuts off
power to all electrical components) with an optional
lockout feature and a 24 hr. timer. It requires a single
circuit 120 volt / 30 amp feed.
Typical Applications Include:
• Spray Irrigation
• Pumping to Gravel Drain Fields
• Pumping to Low Pressure Dosing Systems
• Pumping to Leaching Chambers or any disposal
method requiring a pump where 24 hr.
– 15 minute
increment timed dosing is required.
Equipment Included:
1
– Air Pump
1
– Polyethylene OPS
®
Base & Enclosure
1
– Electrical Control w/ 24 hr. – 15 min. Timer
Floats Switches Required:
1
– Water Pump On/Off Float
1
– Pump Tank High Level Alarm Float
Optional Float Switch:
1
– Pump Tank Timer Override Float
Small Components Include:
Wiring harnesses, electrical connectors, liquid tight
compression fittings, air tubing, shraeder valve,
audible alarm, visual alarm, and various other
components which provide for integration of the
OPS
®
.
50-32 Series OPS
®
Micro-Dose
This OPS
®
provides total control of the aerobic unit
and pump tank including air pump, water pump and
alarms. Other features include high-level override,
two-branch circuit breakers, separate disconnect
switch (which cuts off power to all electrical
components) with an optional lockout feature with a
fully adjustable repeat cycle (micro-dosing) timer. It
requires a single circuit 120 volt / 30 amp feed.
Typical Applications Include:
• Drip Irrigation
• Pumping to Gravel Drain Fields
• Pumping to Low Pressure Dosing Systems
• Pumping to Leaching Chambers or any disposal
method requiring a pump where micro-dosing is
desired with single float high level override / high level
alarm.
Equipment Included:
1
– Air Pump
1
– Polyethylene OPS
®
Base & Enclosure
1
– Electrical Control w/ Micro-dosing Timer
Floats Switches Required:
1
– Water Pump On/Off Float
1
– Pump Tank High Level Alarm Float/Timer
Override Float
Small Components Include:
Wiring harnesses, electrical connectors, liquid tight
compression fittings, air tubing, shraeder valve,
audible alarm, visual alarm, and various other
components which provide for integration of the
OPS
®
.
Содержание AP Series
Страница 1: ......
Страница 15: ...Appendix 3 Technical Manual for Timers Grasslin 24 Hr Timer Omeron Micro Dose Timer ...
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ...Appendix 5 Drawings AP 500 ATU LPA 500 ATU AP 600 ATU AP 750 ATU AP 1000 ATU AP 1500 ATU ...