8-5: Systems Troubleshooting
2.0 Turns over but will not start; there is no spark.
(To check for spark, refer to
engine manual.)
2.1 The recovery tank is full.
Drain the tank.
2.2
The recovery tank float is
faulty.
Inspect the float. Repair or replace as necessary.
2.3 The engine ignition
system in faulty.
Refer to a qualified service technician for further
troubleshooting.
2.4 The water box is empty
Attach an inlet garden hose to fill the water box.
If too many attempts are made to start the
engine prior to filling the water box, it is
possible to flood the engine (see step 3.3 in
the next section)..
3.0 Turns over but will not start; there is spark.
(To check for spark, refer to engine
manual.)
3.1 fuel is not reaching the
carburetor.
Test for power to the fuel pump. Refer to electrical
Section.
If power is present, inspect the fuel pump. Replace if
necessary.
Inspect the fuel lines between the source and the
carburetor. Repair or replace as necessary.
3.2 The carburetor solenoid is
faulty.
Test for power to the solenoid. Refer to electrical
Section.
If power is present, inspect the solenoid. Replace if
necessary.
3.3
The engine is flooded.
Pull the throttle cable completely and crank until the
engine starts.
3.4 The spark plugs are worn
or dirty.
Inspect and replace as necessary.
3.5 None of the above.
Refer to a qualified service technician for further
troubleshooting.