Systems Troubleshooting: 8-10
VaCUUM SySTeM
1.0 a weak vacuum at wand. The gauge reads normal.
1.1 Blockage in the hoses or
wand tube
Disconnect the hoses and check for an obstruction.
1.2 excessive length of
hose connected to the
truckmount
Do not attach excessive lengths of hose.
2.0 a weak vacuum
2.1 Air leak somewhere in the
vacuum system.
Check the vacuum relief valve for proper adjustment.
Carefully check all the vacuum hoses for a cut or
break.
Check the recovery tank lid gasket.
Make sure the recovery tank drain valve is fully
closed.
2.2 The vacuum blower is
turning too slowly.
Check the rpm of the engine. Adjust as necessary to
3,200 rpm under no vacuum load.
2.3 The vacuum gauge is
defective.
Test the gauge and replace if necessary.
3.0 The vacuum gauge reads too high with no hoses attached
3.1
The filter in recovery tank
is clogged.
Remove and clean or replace as necessary.
3.2 The hose from recovery
tank to the vacuum blower
is collapsed internally.
Inspect and replace as necessary.
4.0 excessive noise produced by the blower
4.1 The blower is low on oil.
Inspect the oil levels and replenish as necessary. Note:
Running the blower with low oil levels can cause severe
damage. If this situation occurs the blower should be
inspected by a qualified service technician.
4.2 The vacuum blower has
internal damage.
Refer to a qualified service technician.