Preparing the unit for operation
OFX
en(us)
Page 25 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
Preparing the unit for operation
NOTICE
Danger of tipping over / danger of slipping due to vibrations
The unit will be damaged
►
Prior to operation, place the unit on a stable, horizontal surface.
Prepare the unit for operation by following the following steps:
1. Check the connector cable for damage. If the connector cable is
damaged, replace it immediately.
2. Check the suction and pressure hose for damage. Replace damaged
hoses immediately.
3. Clean the suction strainer. See page 39 for details.
4. Prior to each use, match the oil type in the unit to the oil type to be
pumped. If you are unsure which type of oil is in the unit or you would like
to use a different type of oil than was previously pumped, completely
drain the pump and replace the filter element.
Different types of oil blend together. Oil properties can change.
5. The unit is ready for the next steps on the following pages.