Selecting operating modes
OFX
en(us)
Page 31 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
8.
Empty the content of the
pressure hose (4.1) into the
depressurized tank.
Wipe off any fluid remaining on
the pressure hose with a cloth.
Wind the pressure hose onto the
hose holder on the unit.
9.
Close the depressurized tank.
10. Turn the collet (3.2) on the hose
coupling (3.1) counterclockwise
to unscrew it.
Turn the hose coupling (3.1)
counterclockwise by ~ 90° and
remove it.
Empty the suction hose by lifting
it so that the fluid in the suction
hose flows back into the tank.
11. Once the suction hose has been
completely drained, remove it
from the tank.
Attach the house coupling (3.1)
and turn it by ~ 90° in a
clockwise direction.
Turn the collet (3.2) in a
clockwise direction by hand.
12. Wipe off any fluid remaining on
the suction hose and lance using
a cloth.
Wind the suction hose, including
the lance, onto the hose holder
on the unit.
13. The filling of depressurized tanks