Errors and troubleshooting
OFX
en(us)
Page 44 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
Resetting overload protection
The unit has a thermal overload protection (6.90) to protect the electric
motor.
If the thermal overload protection has been triggered, the electric motor no
longer runs. Reset the thermal overload protection by pressing the switch.
If the overload protection is triggered again, check the viscosity of the fluid
and the suction and pressure hose for flow rate.
If all conditions are within the permitted range, the cause may be a technical
flaw in the electric motor or pump. Contact HYDAC Customer Service.