Hydraulic diagram
FluidAqua Mobil - FAM10/15-P
en(us)
Page 28 / 124
BEWA FAM10-15-P 4052078 en-us 2015-11-05.doc
2015-11-05
Item Designation
1
Suction strainer
2
AquaSensor AS1000
3
Filling pump
4
Non-return valve
5
Vacuum column
6
Heater (Option)
7
Evacuation pump
8
Check valve at the outlet
9
Fluid filter for the separation of solid particles
10
Differential pressure switch for filter monitoring
11
Fluid filter drainage
13
Air filter and dryer
14
Needle valve for vacuum setting
15
Pressure sensor for vacuum measurement
16
Vacuum pump
19
Vacuum column level sensor
20
Pump to the ContaminationSensor CS1000 (optional)
21
ContaminationSensor CS1000 (Optional)
22
Pressure relief valve CS1000 (optional)
23
Pressure relief valve CS1000 (optional)
24
Float switch, oil pan
25
Vacuum column drainage
26
3/2-directional control valve
27
Temperature sensor (optional for heater)
28
Vacuum pump drainage
29
Level sensor for vacuum pump
30
Ball valve at the inlet (IN)
33
Active carbon filter
34
Condensate separator
35
Venting valve
36
Silencer
37
Condensate separator non-return valve
Содержание FluidAqua Mobil FAM 10-P
Страница 123: ......