Operating mode - MANU - OPERATOR (MANU2).................................63
Operating mode - MANU - OPERATOR (MANU3).................................63
Operating mode - MANU - OPERATOR (MANU4).................................64
Operating mode - SETTINGS (SET) .........................................................65
Set units .................................................................................................65
Set temperature......................................................................................66
Set pressure ...........................................................................................66
Menu2........................................................................................................67
Set (repeat testing interval) times...........................................................68
Read operating-hours counter................................................................68
Reset safety thermostat on the heater.......................................................69
Performing Maintenance ............................................................................70
Function testing of the fault indicator lamp ................................................73
Change Air filter.........................................................................................73
Checking the AquaSensor .........................................................................73
Change the active carbon filter cartridge ...................................................74
Performing maintenance on the condensate separator .............................75
Changing the filter element on the condensate separator ......................76
Checking the fill level on the condensate separator ...............................76
Filling the condensate separator ............................................................76
Cleaning the suction strainer .....................................................................77
Rotary vane vacuum pump components ...................................................78
Performing an oil change .......................................................................79
Replacing the Air De-oiling Element.......................................................80
Replacing the filter element on the fluid filter .............................................81
Testing the Float Switch in the Oil Pan ......................................................86
Checking the settings on the heater (optional) ..........................................86
Error messages / Troubleshooting............................................................87
1. CS+pump switched off. CS fault. Start 10 new attempts with
Reset! ........................................................................................................88
2. Flow at FAM inlet has been too low for 5 minutes. Check the
FAM inlet. ..................................................................................................89
3. FAM outlet is blocked ............................................................................90
4. Error, float switch of rotary vane vacuum pump at fill level Min. /
fill level Overflow........................................................................................91
5. / 6. Error, float switch of vacuum column at fill level Max and/or
fill level Overflow........................................................................................92
11. / 12. / 14. / 15. Cable break .................................................................93
16. No defined value from CS....................................................................95