7.1.3 M3: "Filter to" Function (performing automatic cleaning/flushing)
Purpose
This function of the MODE menu enables immediate control of an external filter pump unit
(e.g. OF5C) to be performed without the switching relays. This is illustrated by the following
example.
Typical Application
Flushing of hydraulic systems and documentation of the oil purity rating achieved by way of
an online printout.
Operation
MODE-key
M1: Measure
M2: M switch
M3: Filter to
M4: Filter from to
start
ok
M5: M autostop
Example 1:
Programming OF 5 C operation (single flushing/cleaning action)
limits
M2:Relais1
ok
start
M3: filtration limit:
(6/6/6) NAS/ISO
LIMITS
+
-
0
1
2
3
4
5
6
7
8
9
or
ok
start
M3: Filter to
LIMITS