Operating and Maintenance Instructions : FCU 2110-5 / FCU 2210-5
Edition 1.10
HYDAC Filtertechnik GmbH
Page 28 of 52
6.3 The Display of the FCU
M1
ISO
68%
Q: 70 ml
19 / 15 / 10
1
3
4
2
M1
2µ: 120345
68%D
Q: 70 ml
1
3
4
2
5µ: 47342
5
1
The FCU is working in mode M1 (purity rating measurement).
2
Measured flow rate displayed (70 ml/min is recommended).
3
Signals the elapsed measurement time as a percentage. Begins at 0%, with the
purity rating being shown again at 100%.
C (cumulative) or D (differential) is displayed behind % sign when particle counts
notation is used.
4
Shows the current purity rating, with each particle size being shown separately
when NAS (not available with FCU 2210-5) or particle counts notation is being used.
The “tendency arrow” (
↓
or
↑
) shows very slight changes which would not otherwise
be reflected by the purity rating reading.
5
Shows the current particle count display mode:
FCU
2110-5
D : differential mode : 2..5µm, 5..15µm, 15..25µm, >25µm
C : cumulative mode : >2µm, >5µm, >15µm, >25µm
FCU
2210-5
D : differential mode : 4..6µm, 6..14µm, 14..21µm, >21µm
C : cumulative mode : >2µm, >6µm, >14µm, >21µm