FAM 15/30 ATEX
Technical data
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 81 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Technical data
FAM 15 ATEX
FAM 30 ATEX FAM 50 ATEX
Filter size
OLF 15
OLF 30
OLF 45
Filter element
N15DMxxx (1x) N15DMxxx (2x) N15DMxxx (3x)
Contents of the pressure chamber
20 l
40 l
60 l
Contamination retention capacity
according to ISO 4572
500 g
1000 g
1500 g
Clogging indicator
VM 2 C.x
VM 2 C.x
VM 2 C.x
Reaction pressure of the differential
contamination display
2 bar
2 bar
2 bar
Pump type
Gear pump
Gear pump
Gear pump
Flow rate at 50 Hz
17 l/min
36 l/min
56 l/min
Operating pressure
4,5 bar
4,5 bar
4,5 bar
Viscosity range
15 … 500
mm²/s
15 … 500
mm²/s
15 … 500
mm²/s
Electrical power consumption
1900 W
2700 W
3200 W
IP class
IP 55
IP 55
IP 55
Length of the electrical connection
cable
10 m
10 m
10 m
Length of hoses
5 m
5 m
5 m
Material hoses
NBR
NBR
NBR
Inlet / outlet
G1½ / G1
G1½ / G1
G1½ / G1
Material of seals
NBR
NBR
NBR
Empty weight
640 kg
660 kg
680 kg
Hydraulic fluid temperature
10 … 70°C
10 … 70°C
10 … 70°C
Ambient temperature
10 … 40°C
10 … 40°C
10 … 40°C
Typical dewatering speed
~ 1 l/h*
~ 1,7 l/h*
~ 2,2 l/h
Minimum water content
100 ppm*
100 ppm*
100 ppm*
Oil: HLP46; dewatering rate in particular dependent on fluid type, viscosity,
temperature, and water content.