FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 48 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
[H9] Wrong phase sequence
Step
DESCRIPTION
Malfunction:
"Wrong motor rotation"
1.
Switch off FAM, pull out mains plug
2
Replacement of two phases on the mains plug, check mains voltage
3.
Plug mains plug back in, switch on main switch
4.
Check direction of rotation in accordance with the direction of rotation
arrow on the pumps
->a. The fault recurs
-> proceed to Step 6.
5.
->b. The fault does not recur
-> proceed to Step 7.
6.
Pull out mains plug, check mains cable and plug, replacing as necessary
7.
The failure is repaired.
NOTICE
Direction of rotation, electric motor
The unit is damaged
►
Each time after the electric motors are replaced, the rotational direction
must be checked in manual operation before commissioning.